2.13  Connection of the “START” and “PEDESTRIAN” commands

The PEDESTRIAN opening command can be connected to any push-

button or N.O. (normally open) contact. If several devices are used, 

they must be connected.

Using terminals 9 and 16 it is possible connect a TIMER to program 

gate opening. The timer contact must be an NO (normally open) con-

tact and must remain closed for as long as the gate remains open. 

If an opening command is connected to terminal 16, it must be con-

nected in parallel.

The START opening command can be connected to 

any push-button or N.O. (normally open) contact.

2.12  Connect the 3 WIRES PHOTO-BEAM

POWER SUPPLY 

TX PHOTOCELL

POWER SUPPLY 

RX PHOTOCELL

+

-

+

-

Photocell receiver.

N.C. contact terminals

-

+

Bring JUMPER AC/DC

as shown in the picture

Voltage:

 24 Vdc

Maximum current:

 300 mA

The TEST light signals that the internal logic is functioning correctly. It must fl ash at one second intervals indicating 

that the internal microprocessor is on and awaiting a command. When the control unit is powered, the warning 

lights, set on the inputs, are ON when the contacts on the inputs are closed toward the common:

Normally the red lights on inputs 

STOP - PHOTO - LSO - LSC - STOP - ALT

 are 

ON

Normally the green lights on the control inputs 

START - PEDESTRIAN

 are 

OFF

STOP      PHOTO      LSO          LSC       START       PED

ALT

Safety edge

2.14  Checking connections

8    9   10 11  12  13 14  15  16 17  18  19

8    9   10 11  12  13 14  15  16 17  18  19

Summary of Contents for START-S3XL

Page 1: ...4 15 16 17 18 19 230 Vac 230 Vac Lamp Lamp MOT common MOT close MOT open Antenna Com 1 and Antenna Com 2 12 24Vdc 12 Vdc STOP FOTO LSO LSC START Pedestrian 24 Vac 24 Vac dc 20 21 Light Fototest Light...

Page 2: ...scription 1 2 Field of application 1 3 Type of installation 1 4 Technical features 2 Installation 4 2 1 Diagram of the control unit and electrical connections 2 2 Description of the electrical connect...

Page 3: ...one of the possible applications for this control unit The risks inherent to the MACHINE and the user s requirements must be analyzed in depth in order to establish how many elements need to be insta...

Page 4: ...ncreases pause time 2 1 Diagram of the control unit and electrical connections 2 Installation Connection of the VOLTAGE line 230 Volt Single phase alternate current The control unit power supply line...

Page 5: ...for all inputs services safety devices coaxial antenna braid Com2 12Vdc 10 Output 12 24 Vdc See Phar 2 6 Common 2 12Vdc 11 Output 12 Vdc maximum current 50mA positive Stop 12 STOP input Foto 13 Input...

Page 6: ...4 3 6 5 8 7 10 9 12 11 If you plan to use the photocells test or a 24V light this connection cannot be used 2 5 Connection of the COURTESY light LIGHT 230 Vac DIP 4 OFF ON CTS 2 1 4 3 6 5 8 7 10 9 12...

Page 7: ...input is NOT used put the DIP 5 on ON If the input SAFETY EDGE is not used make a link 22 23 2 8 Connection of LIMIT SWITCHES LSO and LSC The gure shows the connection of both limit switches however o...

Page 8: ...must repeat the times learning operation with the START com mand The TEST function is compatible with lower devices for example TRANSCEI VER so the gate can have a delay when opening The TEST can be d...

Page 9: ...Connect the 3 WIRES PHOTO BEAM POWER SUPPLY TX PHOTOCELL POWER SUPPLY RX PHOTOCELL Photocell receiver N C contact terminals Bring JUMPER AC DC as shown in the picture Voltage 24 Vdc Maximum current 30...

Page 10: ...stop close stop logic Closes again automatically at the end of the pause time 3 OFF closes again when turned on A complete opening pause and closing cycle is run ONLY if the au tomation is in the open...

Page 11: ...OMPLETE ROLLING CODE FUNCTION PRESS THE BUTTON WHEN YOU ARE LEARNING THE PARTIAL OPENING COMMAND THE L E D WITH PARTIAL ROLLING CODE WILL FLASH ONE TIME WHILE WHILE WHEN THE ROLLING CODE IS COMPLETE T...

Page 12: ...le to delete a single wireless control code ON 2 1 4 3 5 P L1 5 Turning on and programming the unit When the electronic circuit board is turned on if everything has been connected properly the red TES...

Page 13: ...RT to start closing The automation starts in CLOSING mode 8A On SLIDING press START to de ne the point in which the automation is to start decelerating The automation DECELERATES 8B On SWINGING withou...

Page 14: ...start closing The automation starts in CLOSING mode 7 Wait for the automation to stop automatically The automation is in the CLOSED position 8 Set the switch DIP 1 to OFF to return to normal opera ti...

Page 15: ...ns PROBLEM The electronic circuit board does not work the TEST signal light does not ash SOLUTION Check the 4A and 160mA fuses PROBLEM The 160mA fuse is burnt out SOLUTION Check the connections and ma...

Page 16: ...rtain voltage limits Reference to harmonized standards EN 60335 1 2004 108 CE EEC DIRECTIVE 2004 108 CE ISSUED BY THE EUROPEAN COUNCIL on December 15 2004 harmonizing the legislation of the member cou...

Reviews: