telsiu altas START-S3XL Instruction Manual Download Page 4

START-S3XL

Technical Manual

 2

control unit power supply 230Vac

 7

power supply for motor and for fl asher 230Vac

 19

power supply voltage to accessories and to

service and safety inputs

20 

 21

“clean” contacts for light or photocell TEST

or fl ashing light without intermittence circuit

22 

 23

stop coast input + inversion for 1.5 sec

JUMPER

AC/DC

output power supply selection 24Vac 

or 24Vdc on terminals 18 and 19

JUMPER

J-R

activation or deactivation of the radio receiver

DIP

 1-10

function of the control unit

DIP

 11-12

deceleration rate or deceleration excluded

selection

Button 

P

manages wireless codes, regulates force,

increases pause time

2.1 

Diagram of the control unit and electrical connections

2 Installation

Connection of the VOLTAGE line

230 Volt Single-phase alternate current. 

The control unit power supply line must 

always be protected with a magnetother-

mal switch or a pair of 5A fuses.

A differential switch is recommended but 

not indispensable if one is already installed 

on the plant.

                    Connection of the MOTOR

                    

 

    Pay particular attention not to invert 

                    the OPEN and CLOSE poles.

When in doubt as to the correct connection, if 

possible, manually position the automation at the 

midpoint of its stroke. Be ready to stop the system 

using the STOP control!

To be sure that the opening is really “opening”, try 

to block the photocells: if the gate begins to close, 

the connection is incorrect and the motor OPEN 

and CLOSE wires must be inverted.

-4-

Summary of Contents for START-S3XL

Page 1: ...4 15 16 17 18 19 230 Vac 230 Vac Lamp Lamp MOT common MOT close MOT open Antenna Com 1 and Antenna Com 2 12 24Vdc 12 Vdc STOP FOTO LSO LSC START Pedestrian 24 Vac 24 Vac dc 20 21 Light Fototest Light...

Page 2: ...scription 1 2 Field of application 1 3 Type of installation 1 4 Technical features 2 Installation 4 2 1 Diagram of the control unit and electrical connections 2 2 Description of the electrical connect...

Page 3: ...one of the possible applications for this control unit The risks inherent to the MACHINE and the user s requirements must be analyzed in depth in order to establish how many elements need to be insta...

Page 4: ...ncreases pause time 2 1 Diagram of the control unit and electrical connections 2 Installation Connection of the VOLTAGE line 230 Volt Single phase alternate current The control unit power supply line...

Page 5: ...for all inputs services safety devices coaxial antenna braid Com2 12Vdc 10 Output 12 24 Vdc See Phar 2 6 Common 2 12Vdc 11 Output 12 Vdc maximum current 50mA positive Stop 12 STOP input Foto 13 Input...

Page 6: ...4 3 6 5 8 7 10 9 12 11 If you plan to use the photocells test or a 24V light this connection cannot be used 2 5 Connection of the COURTESY light LIGHT 230 Vac DIP 4 OFF ON CTS 2 1 4 3 6 5 8 7 10 9 12...

Page 7: ...input is NOT used put the DIP 5 on ON If the input SAFETY EDGE is not used make a link 22 23 2 8 Connection of LIMIT SWITCHES LSO and LSC The gure shows the connection of both limit switches however o...

Page 8: ...must repeat the times learning operation with the START com mand The TEST function is compatible with lower devices for example TRANSCEI VER so the gate can have a delay when opening The TEST can be d...

Page 9: ...Connect the 3 WIRES PHOTO BEAM POWER SUPPLY TX PHOTOCELL POWER SUPPLY RX PHOTOCELL Photocell receiver N C contact terminals Bring JUMPER AC DC as shown in the picture Voltage 24 Vdc Maximum current 30...

Page 10: ...stop close stop logic Closes again automatically at the end of the pause time 3 OFF closes again when turned on A complete opening pause and closing cycle is run ONLY if the au tomation is in the open...

Page 11: ...OMPLETE ROLLING CODE FUNCTION PRESS THE BUTTON WHEN YOU ARE LEARNING THE PARTIAL OPENING COMMAND THE L E D WITH PARTIAL ROLLING CODE WILL FLASH ONE TIME WHILE WHILE WHEN THE ROLLING CODE IS COMPLETE T...

Page 12: ...le to delete a single wireless control code ON 2 1 4 3 5 P L1 5 Turning on and programming the unit When the electronic circuit board is turned on if everything has been connected properly the red TES...

Page 13: ...RT to start closing The automation starts in CLOSING mode 8A On SLIDING press START to de ne the point in which the automation is to start decelerating The automation DECELERATES 8B On SWINGING withou...

Page 14: ...start closing The automation starts in CLOSING mode 7 Wait for the automation to stop automatically The automation is in the CLOSED position 8 Set the switch DIP 1 to OFF to return to normal opera ti...

Page 15: ...ns PROBLEM The electronic circuit board does not work the TEST signal light does not ash SOLUTION Check the 4A and 160mA fuses PROBLEM The 160mA fuse is burnt out SOLUTION Check the connections and ma...

Page 16: ...rtain voltage limits Reference to harmonized standards EN 60335 1 2004 108 CE EEC DIRECTIVE 2004 108 CE ISSUED BY THE EUROPEAN COUNCIL on December 15 2004 harmonizing the legislation of the member cou...