Using the Jog Wheel
The main user control for the OmniaONE is the easy to use jog wheel with its integral push-switch. Using the
control is both intuitive and efficient, making it easy to navigate the menu structure of the OmniaONE. Processing
changes and system adjustments can be quickly made with ease without having to remember multiple controls, their
positions, and what they do in each menu. The behavior of the OmniaONE's menu system is consistent across pages
and is easy to learn. We believe that you will quickly become comfortable with how it works, and appreciate its
simplicity.
Clockwise rotation moves the highlighting in a menu downward and increases a value when editing parameters.
Counterclockwise rotation moves the highlighting in a menu upward and decreases a value when editing parameters.
Pressing inward on the jog-wheel activates the Enter, Return or Select button function as follows:
Pressing the jog-wheel inward once (also called “clicking”) selects the highlighted menu item or accepts the current
parameter value. Think of it as a vertical mouse button.
Pressing and holding the jog-wheel in for two seconds will switch the LCD screen to a display of the processing
meters so that the gain-reduction activity of the AGC and Limiter sections can be monitored.
Clicking once when the metering screen is displayed will return the display to the menu screen.
OmniaONE Multicast - Use and Operation Manual – Version 0.90
24
Summary of Contents for Omnia ONE Multicast
Page 2: ...OmniaONE Multicast Use and Operation Manual Version 0 90 2 ...
Page 4: ...OmniaONE Multicast Use and Operation Manual Version 0 90 4 ...
Page 48: ...OmniaONE Multicast Use and Operation Manual Version 0 90 48 ...
Page 52: ...OmniaONE Multicast Use and Operation Manual Version 0 90 52 ...
Page 58: ...OmniaONE Multicast Use and Operation Manual Version 0 90 58 ...