Final Limit
Drive
The Drive control controls the depth of final limiting. The amount of gain-reduction occurring in
the final limiter can be monitored on the Process metering bargraph screen. Note, however, that
this meter cannot show extremely fast action in the limiter, so your ear must be the final judge.
LPF Freq (Low Pass Filter Frequency)
This is a key control and is used for matching the audio bandwidth of the processed audio to the
bitrate of a following codec. Setting this control to the proper bandwidth for the codec’s settings
will ensure minimal side effects and aliasing distortion products from the codec process. The
available settings are: 4kHz, 6kHz, 8kHz, 10kHz, 13kHz, 16kHz and 22kHz. These are the
frequencies at which the low pass filter reaches a minimum of 100dB of attenuation.
One of the most important features that an audio processor for codec provisioning must have is a
high quality, low overshoot low pass filter after the final peak control stage. OmniaONE Multicast
offers this feature as a low pass output filter that can be set to one of seven stop band frequencies.
Each of the filters possess minimal passband ripple and are phase linear below cutoff. Response in
the filter stop bands is greater than -100dB.
The following chart recommends low pass filter settings that, in our experience, best complement
the AAC+SBR, MP3, and Windows Media (WMA) codecs. They were derived through thousands
of hours of critical listening and we feel they are very good starting points for achieving the best
overall sound although you may use other settings that you feel are more appropriate for your
particular codec application.
AAC/SBR Output
LPF
MP3
Output LPF
WMA
Output LPF
24kbps 8kHz
24kbps 6kHz
24kbps 5kHz
-
6kHz
32kbps 10kHz 32kbps 6kHz
32kbps 8kHz
48kbps
13kHz – 16kHz 48kbps
8kHz – 10kHz 48kbps
10kHz – 13kHz
64kbps
16kHz
64kbps
10kHz – 16kHz 64kbps
13kHz – 16kHz
!!!--- IMPORTANT NOTE ---!!!
Always set the low pass filter frequency so that it is at or below half the sampling frequency of the encoder.
This must be done in order to comply with the Nyquist Theorem
1
. Doing so will achieve the highest perceived
audio quality.
OmniaONE Multicast - Use and Operation Manual – Version 0.90
39
Summary of Contents for Omnia ONE Multicast
Page 2: ...OmniaONE Multicast Use and Operation Manual Version 0 90 2 ...
Page 4: ...OmniaONE Multicast Use and Operation Manual Version 0 90 4 ...
Page 48: ...OmniaONE Multicast Use and Operation Manual Version 0 90 48 ...
Page 52: ...OmniaONE Multicast Use and Operation Manual Version 0 90 52 ...
Page 58: ...OmniaONE Multicast Use and Operation Manual Version 0 90 58 ...