Events:
o
Panic button:
this event occurs when the emergency key found on the module is
pressed
o
RF transmitter panic:
this event occurs when the emergency button of the RF
transmitter is pressed
o
RF transmitter battery low:
this event indicates that the battery voltage of the
RF transmitter is low. It occurs when the battery voltage drops below 2.2V.
If receiving this event, replace forthwith the battery of the RF transmitter.
o
RF supervision fault:
this event occurs when the easyAID module does not
receive the RF
transmitter’s test report (the transmitter was moved too far from
the module or became unusable due to flat battery or other reason)
o
RF supervision restore:
this event indicates the restoration of the RF
transmitters test report. Is generated when any signal is received from the RF
transmitter after a supervision fault
o
Battery fault:
this event indicates
that the module’s battery voltage is low.
It occurs when the battery voltage drops below the 6.5V level
o
Battery restore:
this event is generated when the battery voltage reaches the
normal 7.4V level after a battery fault
o
Supply voltage fault:
this event occurs when
the module’s supply voltage drops
below the 9V level for at least 3 minutes
o
Supply voltage restore:
this event occurs when the supply voltage rises above
10V for at least 10 seconds after a supply voltage fault
o
Test event:
the periodic test report which is generated as configured in the
“Settings” menu / “State reports” section / “
Test report frequency
” and
“
Test report time
” options
o
Low temperature
: this event occurs when the environmental temperature of the
module drops below the configured minimum temperature value
o
Low temperature restore:
this event occurs when the environmental
temperature of the module restores above the configured minimum temperature
value after a low temperature event
o
High temperature:
this event occurs when the environmental temperature of the
module rises above the configured maximum temperature value
o
High temperature restore:
this event occurs when the environmental
temperature of the module restores below the configured maximum temperature
value after a high temperature event
o
Reminder unacknowledged:
this event occurs if the user does not confirm a
reminder
o
Nurse confirmation:
this event occurs when the social worker/nurse enters the
nurse code on the module when visiting the patient
Default:
pressing this button, the whole event template can be restored to factory
default.