tell gsm easyaid Installation And Application Manual Download Page 10

 

10 

The  battery  of  the  RF  transmitter  needs  to  be  replaced  forthwith  if 

RF  transmitter 

battery low

” event is received, as well as at least yearly, independently of the reception 

of  this  event,  in  order  to  retain  the  operating  range  of  the  transmitter!  The  user  can 
initiate  emergency  alarms  by  5  seconds  using  the  RF  transmitter,  while  from  the 
easyAID unit this can be done at anytime. 

To cancel or revoke an emergency call press the Cancel 

 key while the countdown 

is shown on the digital display. After an emergency alarm is initiated, the device waits 5 
seconds before initiating the call and sending SMS message, which time is available to 
cancel an alarm initiated by mistake. 
When an  emergency  call  is  initiated,  the  device  calls  the  1-4  phone  numbers  in  order, 
and  then  sends  the  configured  SMS  messages.  If  any  of  the  called  numbers/party 
received and confirmed the call, then the device does not initiate further calls to the next 
phone numbers and does not send any SMS messages about this event. 

ATTENTION! Disable voicemail service on the phone numbers to be dialed by the 
device because in case that the given phone number is not available, this causes 
significant delay to the calls and SMS messages to be initiated to the next phone 
numbers!  The  outgoing  calls  which  are  received  by  voicemail  are  considered 
successful by the device!  

 

Confirming an emergency call 

The called party can confirm the emergency call by pressing 

 

key on the phone. If the 

called party receives the call and presses 

 

key on the phone, the device will not initiate 

further calls to the next phone numbers, considers the emergency call process finished, 
therefore will not send any configured SMS messages about this event. 

2.4.5  Confirming a visit 

The social worker can confirm the visit by entering a 4 digit individual  password (nurse 
code)  consisting  of  digits  1,2,3  and  4,  which  has  to  be  previously  configured  with  the 
programming  software.  If  the  password  has  been  entered  correctly,  the  module 
generates 

Nurse  confirmation

”  event  and  initiates  the  calls  and/or  SMS  sending 

configured for this event. 

Entering the confirmation password: 

1)  Keep the Cancel 

 key pressed for at least 5 seconds 

2)  On digital display 

„- - - -” is displayed 

3)  Enter your 4 digit nurse code using the 1-4 function keys 
4)  If the password has been entered correctly 

ok

” is displayed 

5)  In case of wrong password 

Err

” is displayed 

Summary of Contents for gsm easyaid

Page 1: ...GSM easyAID Emergency call system INSTALLATION AND APPLICATION MANUAL for module version v2 07 0098 and higher Document version 1 52 30 08 2016...

Page 2: ...estriction 12 3 Configuring the easyAID unit using the programming software 13 3 1 Configuration through USB connection 13 3 2 Configuration through modem connection 14 3 3 Configuring the parameters...

Page 3: ...onversation with the user thus can help in discovering the point of the emergency call or perhaps the type of sick and allows reassuring the user remotely The device has high sensitivity microphone gr...

Page 4: ...etime of its battery Attention The battery of the RF transmitter has to be replaced forthwith if RF transmitter battery low event is received as well as at least yearly independently of the reception...

Page 5: ...se of transportation or storage follow the steps below Disconnect the power adapter from the module If you have connected the device to USB disconnect it Press the Settings key continuously for at lea...

Page 6: ...In this case the display can be turned on for 30 seconds by pressing Cancel key 2 4 Configurable options in the easyAID unit The following options can be configured in the easyAID module Clock settin...

Page 7: ...ly for 3 seconds to save 8 To add new phone number return to step 5 9 When finished press Cancel key to exit the programming mode The TEL LED is lit green continuously to indicate that there are phone...

Page 8: ...he message after the beep as close as possible to the front of the device After the next beep the module replays the recorded message automatically 7 Keep the Settings key pressed for 3 seconds The ti...

Page 9: ...ich initiates SMS sending or call according to the settings The delay between reminder repetitions and the number of repetitions can be configured using the programming software 2 4 4 Starting an emer...

Page 10: ...ecause in case that the given phone number is not available this causes significant delay to the calls and SMS messages to be initiated to the next phone numbers The outgoing calls which are received...

Page 11: ...assword is 1111 The digital display shows ok then 3 Keep the Cancel key pressed and press once function key 1 or 2 according to the number of the memory slot you wish to assign the given RF transmitte...

Page 12: ...device therefore it may not be the subject of a quality complaint To reduce possible echo phenomenon there is possibility to adjust the speaker volume of the device during a conversation through DTMF...

Page 13: ...which can be purchased separately 3 1 Configuration through USB connection Start the easyAID_GSM_Remoter program Choose the USB option in the Connection menu Power up the easyAID module Connect the m...

Page 14: ...he USB RS232 adapter cable equipped with FTDI chip The programming software detects the connected device automatically Enter the phone number of the easyAID module to be connected in the Phone number...

Page 15: ...requency it can be configured in hours between 1 and 168 how often the module should send a periodic test report message expediently in SMS This report serves for checking if the device operates o Tes...

Page 16: ...se code a code consisting of digits 1 2 3 and 4 can be specified which can be used by the social workers nurses to confirm a visit The preset code can be entered on device using the 1 4 function keys...

Page 17: ...cess of that event will be terminated when the 15 minutes period expires and that specific event will not be reported anymore Specification of the columns of the Custom events menu No the event s ordi...

Page 18: ...occurs when the module s supply voltage drops below the 9V level for at least 3 minutes o Supply voltage restore this event occurs when the supply voltage rises above 10V for at least 10 seconds afte...

Page 19: ...le Firmware update process Power up the easyAID module Establish the connection between the programming software and the easyAID module Select the corresponding firmware file after pressing Browse but...

Page 20: ...s password is different from the password used to enter the user settings The module s password protects the software settings against unauthorized access The user password does not change by changin...

Page 21: ...the Status menu easyAID Module section Firmware version version of the module s firmware and its issue date Internal clock the time setting of the connected module Temperature the measured actual envi...

Page 22: ...y pressing this button when connected to the module State messages section This section shows the module s recent messages with date and time of generation It is possible to select which messages to b...

Page 23: ...d 3 8 Software update The Update menu makes possible to select the programming software s update mode Update if Automatic update option is selected the program searches for new version on the internet...

Page 24: ...inder message after the beep when recording a reminder First reminder when pressing function key 1 if the first reminder s time is set but no message is recorded Second reminder when pressing function...

Page 25: ...e being programmed In normal operation mode is lit green if there are reminders set TEL LED When in programming mode is lit green if the phone number settings are selected Still in programming is lit...

Page 26: ...the SIM card into the opened part with the contacts facing down as shown in the figure above Close back the opened part together with the SIM card Press down carefully and pull forward towards the di...

Page 27: ...ming software In case of low signal achieve better signal by relocating the GSM antenna 6 Technical information 6 1 Technical specification Supply voltage 9 30VDC Nominal current consumption 180mA 12V...

Reviews: