GSM easyAID Emergency call system
INSTALLATION AND APPLICATION MANUAL
for module version v2.07.0098 and higher
Document version: 1.52 30.08.2016
Page 1: ...GSM easyAID Emergency call system INSTALLATION AND APPLICATION MANUAL for module version v2 07 0098 and higher Document version 1 52 30 08 2016...
Page 2: ...estriction 12 3 Configuring the easyAID unit using the programming software 13 3 1 Configuration through USB connection 13 3 2 Configuration through modem connection 14 3 3 Configuring the parameters...
Page 3: ...onversation with the user thus can help in discovering the point of the emergency call or perhaps the type of sick and allows reassuring the user remotely The device has high sensitivity microphone gr...
Page 4: ...etime of its battery Attention The battery of the RF transmitter has to be replaced forthwith if RF transmitter battery low event is received as well as at least yearly independently of the reception...
Page 5: ...se of transportation or storage follow the steps below Disconnect the power adapter from the module If you have connected the device to USB disconnect it Press the Settings key continuously for at lea...
Page 6: ...In this case the display can be turned on for 30 seconds by pressing Cancel key 2 4 Configurable options in the easyAID unit The following options can be configured in the easyAID module Clock settin...
Page 7: ...ly for 3 seconds to save 8 To add new phone number return to step 5 9 When finished press Cancel key to exit the programming mode The TEL LED is lit green continuously to indicate that there are phone...
Page 8: ...he message after the beep as close as possible to the front of the device After the next beep the module replays the recorded message automatically 7 Keep the Settings key pressed for 3 seconds The ti...
Page 9: ...ich initiates SMS sending or call according to the settings The delay between reminder repetitions and the number of repetitions can be configured using the programming software 2 4 4 Starting an emer...
Page 10: ...ecause in case that the given phone number is not available this causes significant delay to the calls and SMS messages to be initiated to the next phone numbers The outgoing calls which are received...
Page 11: ...assword is 1111 The digital display shows ok then 3 Keep the Cancel key pressed and press once function key 1 or 2 according to the number of the memory slot you wish to assign the given RF transmitte...
Page 12: ...device therefore it may not be the subject of a quality complaint To reduce possible echo phenomenon there is possibility to adjust the speaker volume of the device during a conversation through DTMF...
Page 13: ...which can be purchased separately 3 1 Configuration through USB connection Start the easyAID_GSM_Remoter program Choose the USB option in the Connection menu Power up the easyAID module Connect the m...
Page 14: ...he USB RS232 adapter cable equipped with FTDI chip The programming software detects the connected device automatically Enter the phone number of the easyAID module to be connected in the Phone number...
Page 15: ...requency it can be configured in hours between 1 and 168 how often the module should send a periodic test report message expediently in SMS This report serves for checking if the device operates o Tes...
Page 16: ...se code a code consisting of digits 1 2 3 and 4 can be specified which can be used by the social workers nurses to confirm a visit The preset code can be entered on device using the 1 4 function keys...
Page 17: ...cess of that event will be terminated when the 15 minutes period expires and that specific event will not be reported anymore Specification of the columns of the Custom events menu No the event s ordi...
Page 18: ...occurs when the module s supply voltage drops below the 9V level for at least 3 minutes o Supply voltage restore this event occurs when the supply voltage rises above 10V for at least 10 seconds afte...
Page 19: ...le Firmware update process Power up the easyAID module Establish the connection between the programming software and the easyAID module Select the corresponding firmware file after pressing Browse but...
Page 20: ...s password is different from the password used to enter the user settings The module s password protects the software settings against unauthorized access The user password does not change by changin...
Page 21: ...the Status menu easyAID Module section Firmware version version of the module s firmware and its issue date Internal clock the time setting of the connected module Temperature the measured actual envi...
Page 22: ...y pressing this button when connected to the module State messages section This section shows the module s recent messages with date and time of generation It is possible to select which messages to b...
Page 23: ...d 3 8 Software update The Update menu makes possible to select the programming software s update mode Update if Automatic update option is selected the program searches for new version on the internet...
Page 24: ...inder message after the beep when recording a reminder First reminder when pressing function key 1 if the first reminder s time is set but no message is recorded Second reminder when pressing function...
Page 25: ...e being programmed In normal operation mode is lit green if there are reminders set TEL LED When in programming mode is lit green if the phone number settings are selected Still in programming is lit...
Page 26: ...the SIM card into the opened part with the contacts facing down as shown in the figure above Close back the opened part together with the SIM card Press down carefully and pull forward towards the di...
Page 27: ...ming software In case of low signal achieve better signal by relocating the GSM antenna 6 Technical information 6 1 Technical specification Supply voltage 9 30VDC Nominal current consumption 180mA 12V...