background image

 

4

Event reporting directions: 

 

Event 

T1 T2 T3 T4 S1 S2 S3 S4 

Mon. station 

IN1 

x x x x x x x x 

IN2 

x x x x x x x x 

IN1 

restore 

        

IN2 

restore 

        

Voltage 

low 

    

x x    

Voltage 

restore 

    

x x    

Test 

report 

    

x     

 

T1-T4: 

reporting to 1-4 user phone numbers with GSM voice call 

S1-S4: 

reporting to 1-4 user phone numbers in SMS 

Mon. station: 

reporting to monitoring station with GSM voice call (Contact ID protocol) 

1.4 Functions and parameters 

 

Inputs 

The Compact-GSM module has 2 inputs (IN1 and IN2), which can be activated 
depending on the setting with normally open (NO) or normally closed (NC) contacts wired 
to COM connection point. Sensitivity of inputs is 100ms, which means event is generated 
only if the input is activated for at least 100ms. Alarm monitoring delay is 10 seconds for 
each input, which means if an input is activated, the module ignores new signals on the 
respective input for 10 seconds from activation, so no alarm events are generated in this 
period. When the 10s delay expires, the input becomes available again for activation. 

 

Relay output 

The relay output can be activated by initiating a call to the module’s phone number from 
the 4 user phone numbers using identification of caller phone number, or from any phone 
number without identification, depending on the setting. Relay control mode is 
monostable, activation time is adjustable between 0-9999 seconds. Default setting: 1s. 

 

User phone numbers 

Maximum 4 phone number can be set, where the module sends reports with GSM voice 
call and SMS. The maximum length of the phone numbers should not exceed 16 
characters and international format should not contain “+” character (e.g. 0036….). 
Already set phone number can be erased by pressing the „

#

” key instead of entering a 

new number. 

 

Call and SMS limitation 

The module is equipped with internal call and SMS limitation. The function allows 50 
outgoing calls and sending of 50 SMS messages per day.  

 

Confirmation 

Confirmation of alarms sent to user phone numbers (with GSM voice call) may be 
necessary. In this case the module recalls the number until the user confirms the alarm 
event. If the confirmation function is enabled, then the event can be confirmed by 
pressing „

¾

” key and all alarm events (calls and SMS) in progress can be stopped by 

pressing „

#

” key. By default the confirmation function is disabled. 

Summary of Contents for Compact-GSM

Page 1: ...Compact GSM INSTALLATION AND APPLICATION MANUAL for module version v1 21 and higher Rev 1 5 16 12 2009 ...

Page 2: ...ustable parameters 6 2 2 Program menu structure 7 2 3 Structure of SMS containing settings 8 2 4 Modification of event SMS texts 8 3 Module overview 9 4 LED signals 9 5 Wiring diagram 10 6 Installation guide 11 6 1 Mounting 11 6 2 Putting into operation 11 7 Technical details 11 7 1 Technical specification 11 7 2 Contents of the package 11 ...

Page 3: ...ocess Supply voltage monitoring The module sends SMS to the first two user phone numbers and report to the monitoring station in at most 24 hour interval if the supply voltage level falls for at least 1 minute below 11 6VDC or 23 2VDC depending on the power source applying supply voltage above 18VDC already means operation on 24V Event restoration is sent in SMS to the same phone numbers and to mo...

Page 4: ...The relay output can be activated by initiating a call to the module s phone number from the 4 user phone numbers using identification of caller phone number or from any phone number without identification depending on the setting Relay control mode is monostable activation time is adjustable between 0 9999 seconds Default setting 1s User phone numbers Maximum 4 phone number can be set where the m...

Page 5: ...BATTERY OK Periodic test report 602 TEST REPORT User account ID The user account ID is a 4 digit identifier which is necessary for reporting to monitoring station and is supplied by the monitoring station The module supports only decimal characters Default setting 0000 Recordable voice messages For each of the two inputs a voice message can be recorded with a maximum length of 6 seconds each If no...

Page 6: ...n restores all parameters to factory default according to Adjustable parameters table For this keep the button pressed for at least 10 seconds then release see LED signals chapter 2 Programming Programming of the module can be performed through call center For this the program button must be pressed for 3 5 seconds then released Thereafter the module enters the programming mode and accepts call to...

Page 7: ...g station phone number Key 2 Enter user account number Key 3 Event code settings Key 1 Enter event code for input 1 Key 2 Enter event code for input 2 Key 3 Enter event code for low supply voltage Key 4 Enter event code for periodic test report Key 4 Other parameters and settings Key 1 Enter test report period Key 2 SMS forwarding settings Key 1 Enable SMS forwarding Key 0 Disable SMS forwarding K...

Page 8: ...EP Y Supply voltage monitoring setting Low voltage report Y enabled N disabled CALLID CHK N Caller identification Y enabled N disabled 2 4 Modification of event SMS texts If it is needed the default texts of event SMS messages can be modified by sending command SMS to the module The command SMS has to be sent when the module is in programming mode therefore it is recommended to write the command S...

Page 9: ...links with longer intervals Event transmission in progress Green blinks impulsely Red is not lit GSM network is available standby status Green performs a determined number of blinks after pressing the program button GSM signal strength query Orange blinks fast Programming mode Orange is continuously lit Restore settings to factory default reset ...

Page 10: ...10 5 Wiring diagram For Normally Open setting For Normally Closed setting ...

Page 11: ...n the SIM card placed into the module Enable caller ID sending service on the SIM card at the GSM service provider If caller identification is used this service must be enabled on the SIM card placed into the module a few types of SIM cards do not have this function enabled by default Check the SIM card to be placed into its case properly Check the antenna to be fixed properly to the Compact GSM m...

Reviews: