background image

 

5

 

SMS forwarding 

The module can forward incoming SMS messages to the first user phone number. SMS 
forwarding function is enabled by default, if not necessary, can be disabled in the settings 
menu. SMS forwarding is limited to 5 messages per day. 

 

Monitoring station phone number 

The module supports 1 monitoring station phone number, where it reports all events 
using Contact-ID protocol. The maximum length of the phone numbers should not 
exceed 16 characters and international format should not contain “+” character 
(e.g. 0036….). Already set phone number can be erased by pressing the „

#

” key instead 

of entering a new number. 

 

Event codes and SMS texts 

A Contact-ID event code (3 digits) can be assigned to each event, which identifies the 
event at the monitoring station. The SMS texts for events are preset according to the 
following table, but can be modified by sending command SMS to the module. The 
default settings for event codes and SMS texts are the following: 

 

Event 

Contact-ID event code 

SMS text 

Alarm input 1 

130 

ALARM1 

Alarm input 2 

130 

ALARM2 

Low supply voltage 

302 

LOW VOLTAGE 

Voltage restore 

302 

BATTERY OK 

Periodic test report 

602 

TEST REPORT 

 

User account ID 

The user account ID is a 4 digit identifier which is necessary for reporting to monitoring 
station and is supplied by the monitoring station. The module supports only decimal 
characters. Default setting: 0000. 

 

Recordable voice messages 

For each of the two inputs a voice message can be recorded with a maximum length of 6 
seconds each. If no message is recorded, the module uses instead a built-in siren tone 
when calling the user phone numbers. The recorded voice messages cannot be erased 
separately, are automatically replaced with the built-in siren tone if the settings are 
restored to factory default (module reset). 

 

Caller identification 

Caller identification is a security function useful in the course of relay remote control. If 
enabled, the module checks the caller’s phone number and activates the relay only when 
called from one of the 4 user phone numbers. For this it is essential to have the phone 
number information sending service enabled on the caller’s SIM card and in the phone as 
well. At the same time, phone number information detection service must be enabled on 
the SIM card placed into the module. The caller identification function is disabled by 
default, so the relay output may be activated from any phone number. 

Summary of Contents for Compact-GSM

Page 1: ...Compact GSM INSTALLATION AND APPLICATION MANUAL for module version v1 21 and higher Rev 1 5 16 12 2009 ...

Page 2: ...ustable parameters 6 2 2 Program menu structure 7 2 3 Structure of SMS containing settings 8 2 4 Modification of event SMS texts 8 3 Module overview 9 4 LED signals 9 5 Wiring diagram 10 6 Installation guide 11 6 1 Mounting 11 6 2 Putting into operation 11 7 Technical details 11 7 1 Technical specification 11 7 2 Contents of the package 11 ...

Page 3: ...ocess Supply voltage monitoring The module sends SMS to the first two user phone numbers and report to the monitoring station in at most 24 hour interval if the supply voltage level falls for at least 1 minute below 11 6VDC or 23 2VDC depending on the power source applying supply voltage above 18VDC already means operation on 24V Event restoration is sent in SMS to the same phone numbers and to mo...

Page 4: ...The relay output can be activated by initiating a call to the module s phone number from the 4 user phone numbers using identification of caller phone number or from any phone number without identification depending on the setting Relay control mode is monostable activation time is adjustable between 0 9999 seconds Default setting 1s User phone numbers Maximum 4 phone number can be set where the m...

Page 5: ...BATTERY OK Periodic test report 602 TEST REPORT User account ID The user account ID is a 4 digit identifier which is necessary for reporting to monitoring station and is supplied by the monitoring station The module supports only decimal characters Default setting 0000 Recordable voice messages For each of the two inputs a voice message can be recorded with a maximum length of 6 seconds each If no...

Page 6: ...n restores all parameters to factory default according to Adjustable parameters table For this keep the button pressed for at least 10 seconds then release see LED signals chapter 2 Programming Programming of the module can be performed through call center For this the program button must be pressed for 3 5 seconds then released Thereafter the module enters the programming mode and accepts call to...

Page 7: ...g station phone number Key 2 Enter user account number Key 3 Event code settings Key 1 Enter event code for input 1 Key 2 Enter event code for input 2 Key 3 Enter event code for low supply voltage Key 4 Enter event code for periodic test report Key 4 Other parameters and settings Key 1 Enter test report period Key 2 SMS forwarding settings Key 1 Enable SMS forwarding Key 0 Disable SMS forwarding K...

Page 8: ...EP Y Supply voltage monitoring setting Low voltage report Y enabled N disabled CALLID CHK N Caller identification Y enabled N disabled 2 4 Modification of event SMS texts If it is needed the default texts of event SMS messages can be modified by sending command SMS to the module The command SMS has to be sent when the module is in programming mode therefore it is recommended to write the command S...

Page 9: ...links with longer intervals Event transmission in progress Green blinks impulsely Red is not lit GSM network is available standby status Green performs a determined number of blinks after pressing the program button GSM signal strength query Orange blinks fast Programming mode Orange is continuously lit Restore settings to factory default reset ...

Page 10: ...10 5 Wiring diagram For Normally Open setting For Normally Closed setting ...

Page 11: ...n the SIM card placed into the module Enable caller ID sending service on the SIM card at the GSM service provider If caller identification is used this service must be enabled on the SIM card placed into the module a few types of SIM cards do not have this function enabled by default Check the SIM card to be placed into its case properly Check the antenna to be fixed properly to the Compact GSM m...