Wake-up Time
Average Power
Consumption
Low Power Deep Sleep (LPDS)
3ms
115µA
Hibernate
50ms
4µA
Shutdown
1.1s
1µA
Communication ports
5.7.1.
SPI
Module WE866 is considered as a slave when it is interfaced with a Host which acts as
master. In addition to the standard SPI lines (MOSI, MISO, CLK, CS) it can be used also
HOST_INT line. WE866 can interrupt the host using HOST_INT line to initiate the data
transfer over the interface. The SPI interface can work up to a speed of 20MHz.
PAD
Signal
I/O
Function
B2
SPI_MOSI
I
Module data input, Host
data output
A3
SPI_MISO
O
Module data output, Host
data input
A2
SPI_CLK
I
SPI clock from Host to
module
B3
SPI_nCS
I
SPI Chip select (active low)
from Host
B4
HOST_INT
O
Interrupt from Module to
Host (Optional)