GE/GC864-QUAD V2 and GE864-GPS Hardware User Guide
1vv0300915 Rev.5 – 2011-10-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved.
Page 44 of 94
6.3.4.
Parameters for ATEX Applications
In order to integrate the Telit’s modules into an ATEX application, the appropriate reference
standard IEC EN xx and integrations shall be followed.
Below are listed parameters and useful information to integrate the module in your
application:
GE864-QUAD V2
Total capacity: 27.45 uF
Total inductance: 55.20 nH
No voltage upper than supply voltage is present in the module.
No step-up converters are present in the module.
GC864-QUAD V2
Total capacity: 27.45 uF
Total inductance: 55.20 nH
No voltage upper than supply voltage is present in the module.
No step-up converters are present in the module.
GE864-GPS
Total capacity: 33.26 uF
Total inductance: 233 nH
No voltage upper than supply voltage is present in the module.
No step-up converters are present in the module.