background image

Telereef Controller - User Manual V.140313

!

Telereef Controller - User Manual 

!

Table of contents 

!

Understand your Telereef Controller

!

3

!

                                             

First Time Setup

!

4

!

                                                                               

Mount the Telereef Controller

!

4

!

                                                                       

Obtain IP Address and set up system time

!

4

!

                                                 

Understand Web Interface and Setup System Time/Date

!

4

!

                          

Setup an internal fixed IP address and new password

!

5

!

                              

Setup Temperature Probe

!

6

!

                                                                             

Setup pH Probe

!

6

!

                                                                                              

Adjust 10V dimmer output

!

7

!

                                                                            

LCD Display

!

8

!

                                                                                      

Date and Time page

!

8

!

                                                                                       

Sensors Page

!

8

!

                                                                                                 

Dimmers & Sockets status page 

!

8

!

                                                                 

System information

!

8

!

                                                                                       

Further Setup

!

9

!

                                                                                   

Relay Module & Socket Panels

!

9

!

                                                                     

Temperature controller for chiller and heater

!

10

!

                                           

pH controller

!

10

!

                                                                                                

Timers

!

11

!

                                                                                                           

Wireless Dosing Pumps

!

13

!

                                                                              

Alert and Push notification (Prowl / Notify)

!

13

!

                                               

Settings Export/Import and Micro SD Memory

!

14

!

                                         

FTP server for logs backup

!

15

!

                                                                        

Log format

!

15

!

                                                                                                    

Aquarium live image (IP Cam)

!

16

!

                                                                    

Trusted IP

!

17

!

                                                                                                     

Wireless Network Connection

!

17

!

                                                                    

Factory Reset and Network Reset

!

18

!

                                                              

Firmware update

!

18

!

                                                                                          

If problem persists, please contact us at [email protected] for help.

!

19

!

   

Set WDP in pair mode

!

19

!

                                                                                 

Details of Telereef’s Web interface

!

20

!

                                               

Home page

!

20

!

                                                                                                   

Setup page

!

21

!

                                                                                                   

Timer Settings page

!

23

!

                                                                                    

System settings

!

25

!

                                                                                           

Socket name settings

!

26

!

                                                                                  

Temperature settings

!

26

!

                                                                                  

pH Sensor settings

!

27

!

                                                                                      

Wireless Dosing Pump Pair Screen

!

27

!

                                                           

Wireless Dosing Pump Setting Screen

!

27

!

                                                      

2

Summary of Contents for TR1D

Page 1: ...Telereef Controller User Manual V 140313 Telereef Aquarium Controller Model TR1D User Manual 1 ...

Page 2: ...e Socket Panels 9 Temperature controller for chiller and heater 10 pH controller 10 Timers 11 Wireless Dosing Pumps 13 Alert and Push notification Prowl Notify 13 Settings Export Import and Micro SD Memory 14 FTP server for logs backup 15 Log format 15 Aquarium live image IP Cam 16 Trusted IP 17 Wireless Network Connection 17 Factory Reset and Network Reset 18 Firmware update 18 If problem persist...

Page 3: ...ef Controller integrated with Ethernet Module which provides network connectivity able to connect to any existing router out of box Beside network connectivity Telereef Controller also provides 2 4GHz RF wireless connectivity able to connect to Telereef Wireless Devices totally freedom such as Telereef Wireless Dosing Pump TRWDP S1 and other upcoming Telereef Wireless Devices To achieve accurate a...

Page 4: ...ontroller through the network connection 1 Connect Telereef s LAN port to one of the LAN ports on your router Telereef Controller can be connected wirelessly by using a small Traveller Nano Router please refer to Wireless Connection section for details 2 Connect Telereef s DC port to a 12V 2A DC power adapter 3 After connected DC power the LCD backlight will light up and firmware version will be d...

Page 5: ...d IP address and new password From the previous step the IP address obtained from the router is a dynamic IP address which means that it may be changed or occupied by other computer from time to time there will be a chance you may be unable to connect to Telereef Controller with the same IP address later so it is better to use a fixed IP address instead 1 Check the DHCP range of the router DHCP ra...

Page 6: ...dit on Temperature Settings section d At T1 Sensor select the address of the external temperature sensor if the address is not inside the pull down menu please reload this Temperature Settings page and try again e At T2 Sensor select the address of the internal temperature sensor f Push Save button to save the settings Now the big temperature reading on Home page changed shows the temperature of t...

Page 7: ...may need to be readjusted if different power adapter is used Skip this step if you don t have a LED 0 10V Dimmable Driver at this moment 1 Go to Home page push 100 button on White Channel after the page refreshed then push 100 button on Blue channel as well 2 Plugin Dimmer 10V Trim Cable to Dimmer Port B 3 Set multimeter to Voltage connect Red line to multimeter s positive port connect Black line ...

Page 8: ...ime and date Sensors Page Second page of LCD display shows three temperature probe reading and pH value An up arrow or down arrow indicates raising or lowering socket control is activated or Indicates the value is out of safety range Dimmers Sockets status page Third page of LCD display shows current output level of two dimming channels and status of eight relays sockets P1 is corresponding to rel...

Page 9: ...as enough rating to controls the device You can connect Telereef Controller to Relays Sockets module with a signal cables You can purchase this cable from our reseller or make it by yourself easily Most Relay Modules in the market have a six pins connector which is compatible with KF2510 plug just install six pins KF2510 plug on both ends of the cable one end is plug into P1 or P2 port the other e...

Page 10: ...s for you simply push Wizard button on Temperature Settings page input the target temperature of each Temperature Sensor the system will calculates the Cooling range Heating range as well as Alert range according to default 0 2 C fluctuation On chiller and heater usually have their own temperature controllers make sure set the temperature on them to one or two degree celsius more or less than the ...

Page 11: ...also be defined a slow dimming effect will be applied Weekly schedule can also be applied For example if initial output is 0 and the following is defined means both dimming channels will started to slow increasing from 0 at 8am and reached to White Channel 80 Blue Channel 100 at 9am Another example if initial output is 100 means both dimming channels started to slow decreasing from 100 at 6pm and ...

Page 12: ...tomatically after 15 mins This timer can be use on Cabinet light night time observation light etc Another example If Allow Off Dur is set to 00 15 00 the related socket will turn on by default when system started up if the socket manually turn off by user it will be turn on automatically after 15 mins This timer can be use on skimmer turn off the skimmer for cleaning and automatically turn on afte...

Page 13: ...n push OK 9 If the WDP successfully paired message Congratulation WDP paired will display and the Device ID and Firmware Version of WDP will display on same row of the paired address You will also hear two short beep from the WDP The LED indicator on WDP Device will flash every 5 seconds if within signal range 10 If WDP Device cannot be found move the WDP Device closer to the Telereef Controller a...

Page 14: ...Telereef Controller reads system settings and timer schedules from the Micro SD card setting ini as well as current usage information included socket time usage and Wireless Dosing Pump dosage socket log To prevent data loss we suggest to backup the system configuration file setting ini by export from Telereef Controller to a desktop computer when you have made any change to the system If the syst...

Page 15: ...sh System button Inside the System Settings page you will found four settings related to FTP where FTP IP Addr is the IP Address of your FTP Server if the FTP Server is installed on same LAN with Telereef Controller you can input the internal IP Address of that FTP Server If the FTP Server is installed on outside network you need to input the internet IP Address of that FTP Server FTP User Login u...

Page 16: ...dimmer blVal Output percentage of the blue dimmer S1 Socket 1 on off status S2 Socket 2 on off status S3 Socket 3 on off status S4 Socket 4 on off status S5 Socket 5 on off status S6 Socket 6 on off status S7 Socket 7 on off status S8 Socket 8 on off status S1ON Socket 1 time usage in seconds S2ON Socket 2 time usage in seconds S3ON Socket 3 time usage in seconds S4ON Socket 4 time usage in second...

Page 17: ...sit the web interface Telereef Controller will bypass the login procedure and let you go straight into the Home page If your IP Address changes from time to time you can use wildcard character to match a whole range of IP Addresses For example 192 168 2 means all the IP Addresses from 192 168 2 1 to 192 168 2 255 We don t recommend to bypass external IP Address unless you confirmed the external IP...

Page 18: ...ove plug now Telereef Controller will restart and back to factory setting If Telereef Controller cannot be connect because of a wrong network setting you can only reset the network setting back to DHCP mode by using P2 port without erase other settings 1 Power off Telereef Controller by unplug the DC power plug 2 Disconnect relay socket cable from P2 port if any 3 Plug the Reset Plug into P2 port ...

Page 19: ...irst time dpinst x86 exe for Intel CPU dpinst amd64 exe for AMD 64bit CPU 4 Connect USB cable between Arduino board and computer 5 For Windows XP browse drivers folder if ask for driver 6 Double Click update vbs to run update script and start update The update process may takes one or two minutes to completed Please wait until the processing bar indicated the update process reached to the end If t...

Page 20: ...Reload Screen Reload the Home page and refresh all data J Next Event Upcoming schedule event K Sensors All available sensors value and related socket s on off status L Button Increase dimmer output of the channel The output of the channel will fixed on the value and turn into Manual mode ignore schedule settings M Auto Button Switch back the dimmer output to Auto mode Obey schedule settings N Butt...

Page 21: ...Wireless Dosing Pump and the chemical name which assign to this pump b 1ml Button Instant add 1ml of chemical to the aquarium c 5ml Button Instant add 5ml of chemical to the aquarium d 10ml Button Instant add 10ml of chemical to the aquarium e Today accumulated Amount of chemical added today f Stock available Amount of the chemical remains in the container estimated can last for how many days g La...

Page 22: ... discover and pair New Telereef Wireless Dosing Pump unit S Edit Button Setup chemical name pump speed and calibrate wireless dosing pumps T Additive Name The name of additives which connected to the pumps U Device Address Device address assigned to WDP unit V Channel Channel assigned to WDP unit W Remain Additives remain in the storage X Reset Button Clear all calibrated pH data prepare to calibr...

Page 23: ...to run the pumps A Start Starting time of the schedule Time format is hh mm ss system accept input time without second ie hh mm If both Start and Stop remain empty the schedule will runs 24 hours B Stop Stopping time of the schedule Time format is hh mm ss system accept input time without second ie hh mm If both Start and Stop remain empty the schedule will runs 24 hours If only Stop is empty or S...

Page 24: ...hedule to temporary switch off wave pump while feeding A Start Starting time of the schedule Time format is hh mm ss system accept input time without second ie hh mm B Stop Stopping time of the schedule Time format is hh mm ss system accept input time without second ie hh mm C DOW Day of Week selection select which day the schedule is enabled D Socket The socket to be switch off during the time pe...

Page 25: ...mat is hh mm ss system accept input time without second ie hh mm Also accept input seconds instead of time format Eg 90 1 minute and 30 seconds F Socket The socket to be connected to this interval timer System settings A Title The text display on the title bar Can be use to fill in aquarium name B User Name Login user name C Password Login password D Trusted IP Defined a list of trusted IP which c...

Page 26: ...et temperature B Tx Sensor A pull down selection of temperature sensor Device IDs which to be assign to the Tx sensor position C Heater Upper The upper temperature of the heater temperature above this value will switch off related relay socket D Heater Lower The lower temperature of the heater temperature below this value will switch on related relay socket E Heater Socket The relay socket of heat...

Page 27: ...sable beep alert J Push Notification Enable Disable push notification to Smart Phone Wireless Dosing Pump Pair Screen A PA The RF Power Amp setting of the WDP 1 Lowest 4 Maximum Default is 3 B Device ID Version The Device ID and the firmware version of the paired WDP C Pair Unpair Button Button used to pair or unpaid a WDP D Passcode The four characters passcode WDP should matched the passcode in ...

Page 28: ...Minimum running time seconds of dosing pump for each dosage System will calculate how many times need to be run the pump according to this value G Stop WDP schedule when no stock Set whether the timer schedule should be disabled or not if the stocked additive is exhausted H Beep Alert Enable or disable beep alert if out of stock or no respond from WDP I Push Notification Enable or disable push not...

Reviews: