Telereef Controller - User Manual V.140313
!
• Wireless Dosing Pumps
!
Telereef Wireless Dosing Pump WDP need to be paired before use. Please follow the
procedures below to pair the WDP unit.
!
1. Login to Web Interface and go to Setup page.
2. Scroll down to Wireless Dosing Pump Section, push
Pair button
3. Input a four characters password, wireless address
value 1-200 and a wireless channel value 1-99.
Each WDP unit occupied 2 wireless addresses and
1 wireless channel for send and receive data.
System will issue address and channel to new
paired WDP unit starting from the value you input.
Eg. if address 121 and channel 76 is input, first WDP will be assigned address
121/122 and channel 76, second WDP will be assigned 123/124 and channel 77,
third WDP will be assigned 125/126 and channel 78.
4. Make sure you have saved the above settings before go to next step.
5. Put only
ONE
WDP device in Pair Mode (See instruction on WDP manual)
6. Reload Wireless Dosing Pump settings page.
7. If WDP Device is in range and found, message "Found unpaired Telereef WDP" will
display together with the Device ID and Firmware Version.
8. Push “Pair” button on which address you want to assign and then push OK.
9. If the WDP successfully paired, message “Congratulation! WDP paired” will display
and the Device ID and Firmware Version of WDP will display on same row of the
paired address. You will also hear two short beep from the WDP. The LED indicator
on WDP Device will flash every 5 seconds if within signal range.
10.If WDP Device cannot be found, move the WDP Device closer to the Telereef
Controller and try again.
!
!
• Alert and Push notification (Prowl / Notify)
!
!
Telereef Controller provides two kinds of alert method, they are
internal beep sound and push notification to Smart Phone. Under
the following conditions Telereef Controller will issue an alert to one
or both methods.
!
!
• System Restart (Push Notification only)
(Priority: Very low)
!
• Temperature Sensors reading out of range.
(Priority: Very high)
!
• Temperature Sensors not responding.
(Priority: Very high)
!
• pH Sensor out of range.
(Priority: Normal)
!
• Wireless Dosing Pump additive out of stock.
(Priority: Low)
!
• Wireless Dosing Pump not responding.
(Priority: Low)
!
!
Same condition will only alert once within 15 minutes or until the
condition has been fixed.
!
!
There is a buzzer inside Telereef Controller generates beep sound if any above
conditions has occurred, the beep sound can be changed by adjusting the length of beep
and interval between beeps in System Settings page, if the beep is too loud, you may set
13
Telereef Wireless Dosing Pump