Eye
III+
VXB
I
nstallation Guide
Page 25
Installation of
Eye
III
+
VXB
for Remote Monitoring
Procedures:
1.
Install ADSL modem and Internet Router as shown in the connection topology diagram.
Setup the Port mapping for Internet Router so that other PCs on the Internet can “see”
Eye
III+
VXB
using that specific port. A typical port mapping setting is illustrated in
the following diagram.
210.177.50.156
PORT 1024
192.168.0.3
PORT 1024
Auto
connection
Internet
Internet
Router
Eye
III+
VXB
External port
1024
Internal IP
192.168.0.2
Internal port
1024
2.
The IP address assigned by the ISP to you through ADSL modem is dynamic, which means
it will change after certain period of time. In order to make the
Eye
III+
VXB
addressable, you need to apply for our proprietary
sure
LINK
service. Procedures involved
are listed in appendix A.
3.
After successful application of
sure
LINK
service, you will obtain a
sure
LINK
address,
for example “www.your_site.your_company.teleeye.net”.
4.
Follow the steps below to set the
sure
LINK
address and DNS name into
Eye
III+
VXB
.
[ NETWORK SETUP ]
TRANSMITTER IP
. . .
SURELINK
. . .
PROXY SERVER
. . .
GATEWAY IP 192.168.0.1
BUILT-IN WEB SERVER ENABLED
BACK
•
Press [Menu] button to enter the
[MAIN MENU]
, and then select
[TRANSMITTER
SETUP]
->
[NETWORK SETUP]
•
Use the arrow button to select
[SURELINK]
item, press
[Enter]
to
popup the
[SURELINK SETUP]
menu