Warranty

Teledyne Isco One Year Limited Factory Service Warranty*

This warranty exclusively covers Teledyne

Isco

instruments, providing a one-year limited warranty
covering parts and labor.
Any instrument that fails during the warranty period due to
faulty parts or workmanship will be repaired at the factory
at no charge to the customer. Teledyne Isco’s exclusive
liability is limited to repair or replacement of defective
instruments. Teledyne Isco is not liable for consequential
damages.
Teledyne Isco will pay surface transportation charges both
ways within the 48 contiguous United States if

the

instrument proves to be defective within 30 days of
shipment. Throughout the remainder of the warranty period,
the customer will pay to return the instrument to Teledyne
Isco and Teledyne Isco will pay surface transportation to
return the repaired instrument to the customer. Teledyne
Isco will not pay air freight or customer’s packing and
crating charges. This warranty does not cover loss, damage,
or defects resulting from transportation between

the

customer’s facility and the repair facility.

The warranty for any instrument is the one in effect on date
of shipment. The warranty period begins on the shipping
date, unless Teledyne Isco agrees in writing to a different
date.
Excluded from this warranty are normal wear; expendable
items such as desiccant, pH sensors, charts, ribbon, lamps, 
tubing, and glassware; fittings and wetted parts of valves; 
check valves, pistons, piston seals, wash seals, cylinders, 
pulse damper diaphragms, inlet lines and filter elements; 
and damage due to corrosion, misuse, accident, or lack of
proper

installation or

maintenance. This warranty does not 

cover products not sold

under

the

Teledyne

Isco

trademark or for which any other warranty is specifically
stated.
No item may be returned for warranty service without a
return authorization number (RMA) issued by Teledyne
Isco.

This warranty is expressly in lieu of all other warranties
and obligations and Teledyne Isco specifically disclaims
any warranty of merchantability or fitness for

a

particular purpose.

The warrantor is Teledyne Isco, 4700 Superior, Lincoln, NE
68504, U.S.A.

*This warranty applies to the USA and countries where Teledyne Isco does not have an authorized dealer.
Customers in countries outside the USA, where Teledyne Isco has an authorized dealer, should contact 
their Teledyne Isco dealer for warranty service.

Problems can o f t e n   be diagnosed and corrected without returning the instrument to the
factory. Before returning any instrument for repair, please contact the Teledyne Isco Service
Department for instructions and to obtain a return material authorization number (RMA).

Instruments needing factory repair should be packed carefully and shipped to the attention of
the service department. Small, non-fragile items can be sent by insured parcel post.

PLEASE 

WRITE THE RMA NUMBER ON THE OUTSIDE OF THE SHIPPING CONTAINER 

and 

enclose a note explaining the problem.

Shipping Address:

Teledyne Isco - Attention Repair Service
4700 Superior Street
Lincoln, NE 68504 USA

Mailing Address:

Teledyne Isco
PO Box 82531

Lincoln, NE 68501 USA

Phone:

Repair service:

(800) 775-2965 (lab instruments)
(866) 298-6174 (samplers & flow meters)

Sales & General Information: (800) 228-4373 (USA & Canada)

Fax:

(402) 465-3001

Email:

[email protected]

March 2, 2016 P/N 60-1002-040 Rev J

Summary of Contents for TIENet 310 Ex

Page 1: ...TIENet 310 Ex Ultrasonic Level Sensor Installation and Operation Guide Ultrasonic Level Sensor Manual Body 69 4313 010 Copyright 2012 All rights reserved Teledyne Isco Revision E March 2019...

Page 2: ......

Page 3: ...Return Material Authorization RMA specified Be sure to include a note describing the malfunction This will aid in the prompt repair and return of the equipment Teledyne ISCO welcomes suggestions that...

Page 4: ......

Page 5: ...t instrument d une mani re autre que celles qui sont specifi es dans ce manuel la protection fournie de l instrument peut tre affaiblie cela augmentera votre risque de blessure Hazard Severity Levels...

Page 6: ...uct Symboles de s curit Ce symbole signale l existence d instructions importantes relatives au pro duit dans ce manuel Ce symbole signale la pr sence d un danger d lectocution Warnungen und Vorsichtsh...

Page 7: ...2 2 2 2 Connecting the Cable 2 2 2 2 1 Permanent Meters 2 2 2 2 2 Connecting to Signature Portable via a TIENet Receptacle 2 5 2 3 Sensor Installation 2 6 2 3 1 Dead Band 2 7 2 3 2 Submersion and Fou...

Page 8: ...l connections 2 4 2 4 Attach wired terminal strip to case board socket 2 4 2 5 Position and secure the cable 2 5 2 6 How to connect a TIENet plug to the Signature Portable 2 6 2 7 Sensor mounting opti...

Page 9: ...the majority of open channel flow measurement situations 1 1 Description The ultrasonic sensor is mounted over the flow stream The flow meter measures the time interval between transmission of a sound...

Page 10: ...thout connectors For greater distances external connection via conduit and con nection of additional TIENet devices the TIENet Expansion Box is available Bulk TIENet cable may also be used for greater...

Page 11: ...ous Locations 22 to 140 F 30 to 60 C 40 to 158 F 40 to 70 C 40 to 140 F 40 to 60 C Measurement Range Minimum 1 ft 0 3m from sensor to liquid surface Maximum 11 ft 3 3m from sensor to liquid at minimum...

Page 12: ...gnment Cable Clamp The cable clamp is used with the Spreader Bar to secure the mounting of the sensor Wall Mount Bracket This device lets you install the ultra sonic level sensor on a convenient nearb...

Page 13: ...rasonic sensor w connector and 10m cable 60 4314 009 310 Ex Ultrasonic sensor w connector and 23m cable 60 4314 011 310 Ex Ultrasonic sensor w connector Cut to length 60 4314 013 Cable Assembly with T...

Page 14: ...TIENet Model 310 Ex Ultrasonic Level Sensor Section 1 Introduction 1 6...

Page 15: ...the programming steps in Figure 2 14 The beam becomes narrower at shorter distances which can increase difficulty in detecting the return echo If the beam is too wide the sensor may pick up signals fr...

Page 16: ...nnel Refer to Section 2 4 Installation in Hazardous Locations for complete information 2 2 Connecting the Cable External TIENet devices such as the 310 Ex are all connected to the Signature flow meter...

Page 17: ...the TIENet device cable end through the sealing nut and seal and through the cable nut Lightly tighten the sealing nut just enough to hold the cable in place while installing the connector Figure 2 2...

Page 18: ...he cable jacket It is not neces sary to prevent the two braids from coming into contact with each other The drain wires need to be kept very short Figure 2 3 TIENet Device terminal connections 5 Press...

Page 19: ...nclosure Failure to seal conduit could reduce equipment life 8 Close the front panel and fasten it shut with the two Phil lips screws Figure 2 5 Position and secure the cable 2 2 2 Connecting to Signa...

Page 20: ...eum based lubricants will cause the O ring to swell and eventually deterio rate Aerosol silicone lubricant sprays often use petro leum based propellents If you are using an aerosol spray allow a few m...

Page 21: ...ion and Fouling Fouling by grease or solids can cause the sensor to malfunction The sensor is sealed so unless it was exposed to corrosive sub stances temporary accidental submersion should not harm i...

Page 22: ...ent for use in gas hazard zones 0 1 and 2 European standards or Class I Division 1 North American standards The braid drain lead depicted in Figure 2 8 Sensor labeling regarding hazloc installations i...

Page 23: ...n 12 2 4 and IEC 60079 11 Serpentine loop WARNING Do not coil the sensor cable this will form an inductor and create a hazard The cable should be kept as short as is practical If necessary use a serpe...

Page 24: ...paratus i e power supply network interface etc This labeling indicates the maximum input voltage Ui maximum input current Ii and maximum power Pi that can be present at the specified terminals without...

Page 25: ...llations Ui Maximum input voltage Ii Maximum input current Pi Maximum power No objects of 12 5mm or greater shall penetrate gap Spacing between bare wires and other wiring circuitry and earth ground s...

Page 26: ...TIENet Model 310 Ex Ultrasonic Level Sensor Section 2 Installation and Setup for Signature 2 12 Figure 2 9 Hazardous Location Installation Control Drawing Atex...

Page 27: ...TIENet Model 310 Ex Ultrasonic Level Sensor Section 2 Installation and Setup for Signature 2 13 Figure 2 10Hazardous Location Installation Control Drawing CSA...

Page 28: ...2 12 on the following page Note From the Hardware Setup menu Configure refers to defining and selecting the parameters for each connected device The four parameters that will appear for the 310 Ex dev...

Page 29: ...nsor Configuration The sensors are being configured Please wait Smart Sensor Setup TIENet The sensors have been configured XXX Parameter XXX Parameter XXX Parameter 1 XXX Hardware Setup 1 Smart Sensor...

Page 30: ...nel The Maximum Blanking Distance is the distance between the sensor face and the bottom of the channel or zero level You can enter a slightly larger value than calculated if you prefer Figure 2 13Con...

Page 31: ...Then highlight Adjust and press Enter to confirm From this screen you can also update the display to show the current level of the stream Figure 2 14Ultrasonic level adjustment and calibration D d h...

Page 32: ...tion Invalid level display has asterisk by level reading Not scanned Perform a smart sensor scan Not able to achieve signal lock misalignment loose mounting turbulence foam or debris in the water Adju...

Page 33: ...illustrations Refer to the call out in the adjacent table to determine the part number for the item Replacement parts can be purchased by contacting Teledyne Isco s Customer Service Department Teledy...

Page 34: ...w 10m cable 60 4314 005 310 Ex Ultrasonic sensor w 23m cable 60 4314 006 310 Ex Ultrasonic sensor w Cut to length 60 4314 014 310 Ex Ultrasonic sensor w connector and 10m cable 60 4314 009 310 Ex Ult...

Page 35: ...TIENet Model 310 Ex Ultrasonic Level Sensor A 3...

Page 36: ...TIENet Model 310 Ex Ultrasonic Level Sensor A 4...

Page 37: ...ous Substances or Elements in the product O ST O Represent the concentration of the hazardous substance in this component s any homogeneous pieces is lower than the ST standard limitation X ST X X Rep...

Page 38: ......

Page 39: ...ied Body for EC Type Examination EC type Examination Certificate Notified Body for Production Harmonized Safety Standards Other Standards and Specifications used 2017 II 1G Ex ia IIB T4 Ga 40C Ta 60C...

Page 40: ......

Page 41: ...e due to corrosion misuse accident or lack of proper installation or maintenance This warranty does not cover products not sold under the Teledyne Isco trademark or for which any other warranty is spe...

Page 42: ......

Reviews: