MERIDIAN
UNIVERSAL GAS DETECTOR
GAS SENSOR INFORMATION
B-5
USE AND DISCLOSURE OF DATA
Information contained herein is classified as EAR99 under the U.S. Export Administration Regulations. Export, reexport or diversion contrary to U.S. law is
prohibited.
B. Divide 50%LEL by 0.58 K-Factor. This equals 86.2%LEL.
C. Thus, the device’s CALGASCONC parameter should be set to 86%LEL when exposed to 50%LEL methane.
See
Section 5.1.3 Configuring the Setup Menu
.
4. After calibrated, the device should read 86%LEL in Isobutylene scale when 50%LEL methane bottle gas is
applied.
Table B-3: K-Factors for Combustible Cat-Bead Sensors - Methane
Gas/Vapor*
K-Factor (Parameter Field)
K-Factor (Methane Ratio)
Acetaldehyde (C
2
H
4
O)
0.64
0.64
Acetone (C
3
H
6
O)
0.60
0.60
Acetylene (C
2
H
2
)
0.63
0.63
Ammonia (NH
3
)
1.43
1.43
Benzene (C
6
H
6
)
0.45
0.45
1,3-Butadiene (C
4
H
6
)
0.45
0.45
n-Butane (C
4
H
10
)
0.52
0.52
Isobutane (C
4
H
10
)
0.45
0.45
Isobutylene (C
4
H
8
)
0.58
0.58
Butyl Acetate (C
6
H
12
O
2
)
0.40
0.40
n-Butyl Alcohol (C
4
H
10
O)
0.45
0.45
Chlorobenzene (C
6
H
5
Cl)
0.38
0.38
Cyclohexane (C
6
H
12
)
0.46
0.46
Diethyl ether (C
4
H
10
O)
0.50
0.50
n-Decane (C
10
H
22
)
0.29
0.29
Ethane (C
2
H
6
)
0.68
0.68
Ethyl Acetate (C
4
H
8
O
2
)
0.46
0.46
Ethyl Alcohol (C
2
H
6
O)
0.63
0.63
Ethylbenzene (C
8
H
10
)
0.41
0.41
Ethylene (C
2
H
4
)
0.63
0.63
Ethylene Oxide (C
2
H
4
O)
0.49
0.49