A.3. Toxic (E-Chem) Sensor Specifications
The Company offers two (2) types of E-Chem Sensors: Standard and Rock Solid.
• Standard E-Chem Sensors – Capable of detecting higher concentrations than the Rock Solid E-Chem Sen
-
sors.
• Rock Solid E-Chem Sensors – Baseline is more stable and accurate. Allows lower range and lower alarm set
-
tings. Less susceptible to interference gases. Faster response and recovery time then Standard E-Chem Sen
-
sors.
Table A-3: Toxic (E-Chem) Sensor Specifications
096-34
73-XX
Gas
Symbol
Type**
RH Rating***
Operating T
em
p
Range (
°C
)
Default Range
(PP
M
)****
Range
(M
in. to M
ax.)
(PP
M
)*****
Default Cal G
as
03
Ammonia
NH
3
Std. G
-5 to 50
(-40 to 50)#
100
50 to 500
NH
3
24
Bromine
Br
2
RS
H
-40 to 50
10
1 to 10
Cl
2
01
Carbon Monoxide
CO Std. G
-40 to 50
100 50 to 1000
CO
20
Chlorine
Cl
2
RS
H
-40 to 50
5
1 to 30
Cl
2
21
Chlorine
Cl
2
RS*
L
-40 to 50
5
1 to 30
Cl
2
37
Chlorine Dioxide
ClO
2
RS* H
-40 to 50
5
1 to 5
Cl
2
38
Chlorine Dioxide
ClO
2
RS
L
-40 to 50
5
1 to 5
Cl
2
22
Fluorine
F
2
RS
H
-40 to 50
5
1 to 5
Cl
2
23
Fluorine
F
2
RS*
L
-40 to 50
1
1 to 5
Cl
2
12
Hydrogen
H
2
Std. H
-40 to 50
4%
1 to 4%
H
2
25
Hydrogen Chloride
HCl RS* H
-25 to 50
10
1 to 25
SO
2
26
Hydrogen Chloride
HCl
RS
L
-25 to 50
10
1 to 25
SO
2
11
Hydrogen Cyanide
HCN
Std.
*
G
-20 to 50
25
25 to 100 HCN
27
Hydrogen Fluoride
HF
RS* H
-25 to 50
10
1 to 30
SO
2
28
Hydrogen Fluoride
HF
RS
L
-25 to 50
10
1 to 30
SO
2