Linea GigE Series Camera
Operational Reference
•
55
Display Name
Feature & Values
Description
Device Version
& View
Flat Field Correction Mode flatfieldCorrectionMode
Sets the mode for the Flat Field correction.
1.00
Beginner
DFNC
Off
Off Flat Field Correction is disabled.
Active
Active Flat Field Correction is enabled.
Calibration
Calibration When selected, the camera is configured for flat
field correction calibration. The device may
automatically adjust some of its features when
calibrate mode is enabled. The features that are
automatically adjusted are device specific. The
device will not restore these features when the
Flat Field Correction Mode feature is changed from
Calibrate mode to another mode.
Flat Field Correction
Current Active Set
flatfieldCorrectionCurrentActiveSet
Specifies the current set of Flat Field coefficients to
use. User data is uploaded via the file access
feature.
Feature used when flatfieldCorrectionMode is
Active. In Calibration, changing this feature has
no effect unless you save the FFC, where this
feature defines where to save the values. This
feature also can be used to copy FFC sets.
1.00
Beginner
DFNC
Factory Flatfield
FactoryFlatfield Sets the factory Flat Field coefficient table as the
current Flat Field.
User Flatfield 1
UserFlatfield1 Sets User Flat Field 1 coefficient table as the
current Flat Field.
User Flatfield 2
UserFlatfield2 Sets User Flat Field 2 coefficient table as the
current Flat Field.
User Flatfield 3
UserFlatfield3 Sets User Flat Field 3 coefficient table as the
current Flat Field.
User Flatfield 4
UserFlatfield4 Sets User Flat Field 4 coefficient table as the
current Flat Field.
Flat Field Correction Type
flatfieldCorrectionType
Specifies the Flat Field correction type.
1.00
Guru
DFNC
Line-Based
LineBase Flat field correction is based on an individual line
(FlatLine).
flatfieldCorrectionAlgorithm
Specifies the Flat Field correction algorithm to use.
1.00
Guru
DFNC
Method 1
Method1 The following formula is used to calculate the flat
field corrected pixel: newPixelValue[x] =
(sensorPixelValue[x] - FFCOffset[x]) * FFCGain[x]
Calibration Algorithm
flatfieldCorrectionCalibrationAlgorit
hm
Specifies the flatfield calibration algorithm to use.
1.00
Guru
DFNC
Basic
Basic Direct calculation of coefficients based on average
line values and target.
Low Pass Filter
LowPass Apply a low pass filter to average line prior to
calculating coefficients. Used when target is not
uniformly white or it is not possible to defocus
image.
Flat Field Calibration
Target
flatfieldCalibrationTarget
Sets the target pixel value for the gain (PRNU)
calibration.
1.00
Guru
DFNC
Flat Field Calibration
Sample Size
flatfieldCalibrationSampleSize
Set flat field calibration sample size (number of
lines to sum)
1.00
Guru
DFNC
2048
Lines_2048 2048
4096
Lines_4096 4096
Flat Field Calibration
Offset X
flatfieldCalibrationROIOffsetX
Sets the ROI Offset X
1.00
Guru
DFNC
Flat Field Calibration
Width
flatfieldCalibrationROIWidth
Sets the ROI Width
1.00
Guru
DFNC