50
•
Operational Reference
Linea GigE Series Camera
Counter 2 End
Counter2End Start Timer on Counter 2 End event.
Timer Line Activation
timerStartLineActivation
Select the trigger activation mode which starts the
timer.
1.00
Expert
DFNC
Rising Edge
RisingEdge Starts counter on rising edge of the selected signal.
Falling Edge
FallingEdge Starts counter on falling edge of the selected
signal.
Any Edge
AnyEdge Starts counter on the falling or rising edge of the
selected signal.
Timer Delay
timerDelay
Sets the duration (in microseconds) of the delay to
apply at the reception of a trigger before starting
the timer.
1.00
Expert
DFNC
Timer Duration
timerDuration
Sets the duration (in microseconds) of the timer
pulse.
1.00
Expert
DFNC
Timer Value
timerValue
Reads the current value (in microseconds) of the
selected timer.
1.00
Expert
DFNC
Timer Reset
timerReset
Resets the timer to 0.
1.00
Expert
DFNC
Counter and Timer Group Block Diagram
Line Selector =
Line 1 to 6
Physical
Line
Event Driven
Input
inverter
Output
inverter
Software Driven
Pulse
generator
LineStatus
Trigger
Line
Activation
Trigger Signal
Timer
TimerEnd Event
CounterEnd Event
Software Trigger
Cmd
Line
Mode
Input
or
ouput
Input
Output
Timer and Counter Module
Counter
Line
Debouncer
Event Driven
Trigger
Source
Trigger Module
Output
Line
Source
Signal Driven
Software Driven
Line
Detection
Level