Nano Series GigE Vision Camera
Operational Reference
•
179
Acquisition and Transfer Control Feature Descriptions
The following table describes these parameters along with their view attribute and minimum
camera firmware version required. Additionally the Device Version column will indicate which
parameter is a member of the DALSA Features Naming Convention (denoted by DFNC), versus the
GenICam Standard Features Naming Convention (SFNC tag is not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Genie Nano capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by
green text
for easy identification.
Display Name
Feature & Values
Description
Device Version
& View
Acquisition Status
Selector
AcquisitionStatusSelector
Selects the internal acquisition signal to read using
AcquisitionStatus.
1.00
Expert
Acquisition Active
AcquisitionActive Device is currently doing an acquisition of one or
many frames.
Acquisition Trigger Wait
AcquisitionTriggerWait Device is currently waiting for a trigger to start the
acquisition.
(
Ver. 1.05
)
Acquisition Status
AcquisitionStatus
Reads the state of the internal acquisition signal
selected using the Acquisition Status Selector feature.
(i.e. False / True)
1.00
Expert
Acquisition Mode
AcquisitionMode
Set the acquisition mode of the device. It defines the
number of frames to capture during an acquisition
and the way the acquisition stops.
1.00
Beginner
Single Frame
SingleFrame One frame is captured for each AcquisitionStart
Command. An AcquisitionStop occurs at the end of
the Active Frame.
Multi-Frame
MultiFrame A sequence of frames is captured for each
AcquisitionStart Command. The number of frames is
specified by AcquisitionFrameCount feature. An
AcquisitionStop occurs at the end of the Active
Frame(s)
Continuous
Continuous Frames are captured continuously with
AcquisitionStart until stopped with the AcquisitionStop
command.
Acquisition Frame Count AcquisitionFrameCount
Number of frames to be acquired in MultiFrame
acquisition mode.
1.00
Beginner
Acquisition Arm Cmd
AcquisitionArm
Arms the device before an AcquisitionStart command.
This optional command validates all the current
features for consistency and prepares the device for a
fast start of the acquisition. If not used explicitly, this
command is automatically executed at the first
AcquisitionStart but will not be repeated for
subsequent ones unless a data transfer related
feature is changed in the device.
1.00
Guru
Acquisition Start Cmd
AcquisitionStart
Start image capture using the currently selected
acquisition mode. The number of frames captured is
specified by AcquisitionMode feature.
1.00
Beginner
Acquisition Stop Cmd
AcquisitionStop
Stops the Acquisition of the device at the end of the
current frame unless the triggerFrameCount feature is
greater than 1. (WO)
1.00
Beginner
AcquisitionAbort
Aborts the acquisition immediately. This will end the
capture without completing the current Frame or
aborts waiting on a trigger. If no acquisition is in
progress, the command is ignored.
1.00
Beginner
Transfer Control
TransferControlMode
Sets the method used to control the transfer.
1.00
Summary of Contents for Genie Monochrome Series M1280
Page 179: ...Nano Series GigE Vision Camera Operational Reference 177...
Page 215: ...Nano Series GigE Vision Camera Technical Specifications 213 Note Genie Nano with C or CS Mount...
Page 237: ...Nano Series GigE Vision Camera Technical Specifications 235 Models M C5100 M C4090...
Page 252: ...250 Additional Reference Information Nano Series GigE Vision Camera...