126
•
Operational Reference
Nano Series GigE Vision Camera
Example: Counter Start Source = OFF
Countermode=OFF
Counter is
IDLE
Counter
Overflow
CounterEnd Event Generated
Counter is
Active
CounterStartSource=OFF
CounterWait
Trigger
Counter is incrementing
Countermode=Active
CounterResetSource=OFF
CounterResetSource=Event
Counter Reset CMD
Counter
Completed
CounterResetSource=CounterEnd
CounterStartSource=OFF
0
•
The counter starts on the counterReset Cmd.
•
The counter continues unless a new counterReset Cmd is received, which then restarts the
counter at 00.
•
When Counter Reset Source= ‘Event’ or ‘CounterEnd’ the counter is reset to 00 but does
not restart counting, until the next CounterReset Cmd.
Example: Counter Start Source = CounterEnd (itself)
Countermode=OFF
Counter is
IDLE
CounterEnd Event Generated
Counter is
Active
CounterStartSource=
CounterEnd (itself)
CounterWait
Trigger
Counter is incrementing
Countermode=Active
Counter Reset CMD
Counter
Completed
CounterResetSource=CounterEnd
CounterStartSource=CounterEnd (itself)
0
•
Counter starts when Counter Mode is set to Active.
•
A Counter Reset CMD will reset the counter to 00 and it then continues counting.
•
counterResetSource must be set to CounterEnd. When the counterValue feature reaches the
counterDuration value an event is generated and the counter is reset to 00, then continues.
Summary of Contents for Genie Monochrome Series M1280
Page 179: ...Nano Series GigE Vision Camera Operational Reference 177...
Page 215: ...Nano Series GigE Vision Camera Technical Specifications 213 Note Genie Nano with C or CS Mount...
Page 237: ...Nano Series GigE Vision Camera Technical Specifications 235 Models M C5100 M C4090...
Page 252: ...250 Additional Reference Information Nano Series GigE Vision Camera...
Page 254: ...252 Additional Reference Information Nano Series GigE Vision Camera...