U
SER
M
ANUAL
M
ONOCHROME
–
R
EV
J
–
05/2017
P
A G E
|
29
7.5
Image Control
Save Image
(
SaveImageControl
) : control the recording of the image in the camera
This command is available in the CommCam “Image Control” section :
Read function (ASCII): “
r recl
”;
Returned by the camera :
“0” : No Record in Progress
“1” : Record in Progress
Write function (ASCII): “
w recl
” <value> :
“0” : Stop Recording
“1” : Start Recording
Play Image
(
PlayImageControl
) : control the Replay of the image in the camera
This command is available in the CommCam “Image Control” section :
Read function (ASCII): “
r play
”;
Returned by the camera :
“0” : Camera display the “Live Image”
“1” : Camera display recorded Image
Write function (ASCII): “
w play
” <value> :
“0” : Start Playing Live Image
“1” : Start Playing Recorded Image
FPN coefficients modification :
Direct access to the Saved Image in Memory.
The Overall size of the Memory zone is 2 x 4096 Bytes :
Read function (ASCII): “
r alin
”
This Function is available only with the version 2.1.0 of the Firmware
GenCP address
ASCII
command
GenICam
command
Size
R/W
Description
0x12250
recl
SaveImageControl
4
RW Record the Current Image
Read :
0 : No Record in Progress
1 : Record in Progress
Write :
0 : Stop Record
1 : Start Record
0x12254
play
PlayImageControl
4
RW Play Image :
0 : Play “Live” Image
1 : Play Recorded Image
0x120000
alin
ImageControlAccess
2*4096
RO Manual access to the recorded Image