7.9.2
Save & Restore Settings
The settings (or Main configuration) of the Camera can be saved in 4 different User banks and one Integrator bank.
This setting includes also the FFC and LUT enable
This function is available in the Save & Restore Settings section :
Load settings from Bank :
Allows to restore the Camera settings.
Read function : “
r rcfg
” (ASCII): Get the current Tap Bank in use
Write function : “
w rcfg <val>
” (ASCII): Load settings from bank <val> (0: Factory , 1 to
4 for Users, 5 for Integrator)
Save settings to Bank :
Allows to save the Camera settings in User or Integrator Bank
Write function : “
w scfg
<val>
” (ASCII): Save the current settings in the User bank <val>
(1 to 4 for User, 5 for Integrator)
The integrator bank (User Set5) can be written only if the Camera is set in integrator
mode (Privilege level = 1). This integrator bank can be used as a « Factory default » by a
system integrator.
Configuration Bank Usage
Ram Memory
Sav
Load
Factory
Integrator
(Bank 5)
User1
User2
User3
User4
User banks