Teledyne API Model 465L O3 Monitor Operation Manual
58
Teledyne API Model 465L O
3
Monitor Manual
05509G DCN6806
8.5.3.
Determining a Dynamically Assigned IP Address
(DHCP Mode)
The
DeviceInstaller
software application (See Section 8.5) can be used to search a
network for instruments and determine the IP Address assigned by a DHCP server.
1.
Click
Start
->
Programs
->
Lantronix
DeviceInstaller
->
DeviceInstaller.
If your PC has more than one network adapter, a message displays. Select an
adapter and click
OK
.
2.
Click on the
Search
icon. After a moment a list of instruments on the
network will be displayed. The 465L should be listed as an
XPORT-IAP
type
device.
3.
Double-click on the device in the right-hand section of the
DeviceInstaller
window; a list of configuration parameters will be shown, including the IP
Address. If multiple devices are shown, the correct one can be determined by
matching the Hardware Address shown with the address printed on the label
of the Ethernet module in the 465L. Note that the instrument cover must be
removed to inspect this address in the instrument.
8.5.4.
Manually Assigning a Static IP Address
For applications where the IP Address must remain constant, a static IP Address can
be manually assigned to the instrument and the DHCP function must be disabled.
1.
Click
Start
->
Programs
->
Lantronix
DeviceInstaller
->
DeviceInstaller.
If your PC has more than one network adapter, a message displays. Select an
adapter and click
OK
.
Note:
If the unit already has an IP address (e.g., DHCP has assigned
an IP address), click the Search icon and select the unit from the list of
Lantronix device servers on the local network.
2.
Click the
Assign IP
icon.
3.
If prompted, enter the hardware address (on the product label) and click
Next
.
4.
Select
Assign a specific IP address
and click
Next
.
5.
Enter the
IP address
. The
Subnet mask
displays automatically based on
the IP address; if desired, you may change it. On a local network, you can
leave the
Default gateway
blank (all zeros). Click
Next
.
6.
Click the
Assign
button and wait several seconds until a confirmation
message displays. Click
Finish
.
7.
Select the device from the main window list and select
Ping
from the
Tools
menu. The Ping Device dialog box shows the IP address of the selected unit.
8.
From the
Tools
menu, click the
Ping
button. The results display in the Status
window. Click the
Clear Status
button to clear the window so you can ping
the device again.
Summary of Contents for 465L