MULTIXPLO AND MULTITOX DETECTORS
OPERATING MANUAL
NOSP17665
Revision 02a
13
3
Performances
Expected lifetime in standard conditions:
•
>5 years for DG-TX7
•
>10 years for DG-TT7-K
This lifetime can be reduced in case of exposure to dusty environments.
For catalytic version, some compounds are known to poison sensors. These
include, organometallic, silicone and some halogenated compounds
PERFORMANCES
DG-TX7-X
DG-TT7-K
Detector
CH4
H2
C4H10
H
2
CO
2
He
Ranges
100 % L.E.L.
(5.0 %vol)
100 % L.E.L.
(4.0 %vol)
100 % L.E.L.
(1.9 %vol)
5%vol
20%vol
100%vol
20%vol
5% vol
20% vol
100% vol
Relative sensibility
1.70
1.70
1.00
τ
(0-90%) (sec)
< 15
< 10
< 20
< 10
< 30
< 10
Zero point stability
< 3
< 3
< 3
< 3
< 3
< 3
Sensibility drift
< 3
< 3
< 3
< 3
< 3
< 3
T° range (°C)
-40 / +65
-40 / +65
-40 / +65
-40 / +65
-40 / +65
-40 / +65
Temperature zero drift
< 2
< 2
< 2
< 3
< 5
< 3
Temperature sensitivity drift
< 3
< 3
< 3
< 3
< 5
< 3
Linearity
< 3
< 1
< 3
< 2
< 2
< 2
Repeatability
< 1
< 1
< 1
< 1
< 1
< 1
Expected service life
>5
>5
>5
10
10
10
Relative humidity (% HR)
0 – 95 % condensation free
15 – 95 % condensation free
Pressure range
Pa
±
10%
Cross sensitivity
All inflammable compounds
All gases with either very high or very low thermal
conductivity
Poisons
Silicon compounds, certain halogen compounds,
and some organometallic compounds.
None
Effect of O
2
–enriched
or
depleted atmospheres
15 % O
2
min.
10 % O
2
min.
15 % O
2
min.
None
Biasing time
90 sec
120 sec
Summary of Contents for Everywhereyoulook DG-TT7-K
Page 18: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 12 NOSP17665 Revision 02a...
Page 34: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 28 NOSP17665 Revision 02a...
Page 58: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 52 NOSP17665 Revision 02a...
Page 66: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 60 NOSP17665 Revision 02a...
Page 68: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 62 NOSP17665 Revision 02a...
Page 69: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL NOSP17665 Revision 02a 63...
Page 70: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 64 NOSP17665 Revision 02a...
Page 71: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL NOSP17665 Revision 02a 65...