MULTIXPLO AND MULTITOX DETECTORS
OPERATING MANUAL
NOSP17665
Revision 02a
31
Display time:
The detector displays concentration or status. Depending on events, the detector displays
cyclically important information according to the context: unit, gas, label, fault, alarms, inhibition
and the time remaining inhibition….
Output current (4-20mA ou 0-22mA) :
It can be modified by the user. See §6.8.6.2.
Negative concentration:
The negative concentration display allows to anticipate the zero-drift fault.
It can be modified by the user. See § 0.
6.4
Alarm indication
When an alarm status is confirmed, the backlight turns red. Moreover, the display indicates the
alarm level and the current concentration.
The remaining information which is usually recorded in the display cycle are not provided
anymore, in order to keep the detection and current alarm level as a priority.
If the alarm memorization is enabled, the backlight light remains red and the alarm indication
appears in the display cycle until the alarm is acknowledged with the TLU or the TLH700 or the
magnetic wand or the detector is powered off, then powered on again.
If the alarm memorization is disabled, the backlight turns green when the alarm fades.
If the device is used in a safety loop in a potentially explosive area (EN60079-
29-1), the upper alarm must be memorized, and a manual action must be taken
to clear it.
6.5
Display indication
The 4 Digits display provides several information, depending on the state of the device:
Starting:
•
Display cycle: concentration and measuring scale (25 then % then LIE then CH4, for
example)
•
Alternately indicates the inhibition mode and the warming up remaining time
Summary of Contents for Everywhereyoulook DG-TT7-K
Page 18: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 12 NOSP17665 Revision 02a...
Page 34: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 28 NOSP17665 Revision 02a...
Page 58: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 52 NOSP17665 Revision 02a...
Page 66: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 60 NOSP17665 Revision 02a...
Page 68: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 62 NOSP17665 Revision 02a...
Page 69: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL NOSP17665 Revision 02a 63...
Page 70: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL 64 NOSP17665 Revision 02a...
Page 71: ...MULTIXPLO AND MULTITOX DETECTORS OPERATING MANUAL NOSP17665 Revision 02a 65...