Frontline Harmony Hardware & Software User Manual
47
LL/TIM/MAS/BV-07-C
Extended Advertising, Secondary Channel, Latest Transmission to Advertiser
– LE Coded PHY
LL/TIM/SCN/BV-01-C
Extended Scanning, Secondary Channel, Earliest Transmission to Scanner –
LE 1M PHY, Core 5.0
LL/TIM/SCN/BV-02-C
Extended Scanning, Secondary Channel, Earliest Transmission to Scanner, LE
Coded PHY, Core 5.0
LL/TIM/SCN/BV-03-C
Extended Scanning, Secondary Channel, Latest Transmission to Scanner, LE
Coded PHY, Core 5.0
LL/TIM/SCN/BV-04-C
Extended Scanning, Secondary Channel, Earliest Transmission to Scanner –
LE 2M PHY, Core 5.0
LL/TIM/SCN/BV-05-C
Extended Scanning, Secondary Channel, Earliest Transmission to Scanner –
LE 1M PHY, Core 5.1
LL/TIM/SCN/BV-06-C
Extended Scanning, Secondary Channel, Earliest Transmission to Scanner –
LE 2M PHY, Core 5.1
LL/TIM/SCN/BV-07-C
Extended Scanning, Secondary Channel, Earliest Transmission to Scanner, LE
Coded PHY, Core 5.1
LL/TIM/SCN/BV-08-C
Extended Scanning, Secondary Channel, Latest Transmission to Scanner, LE
Coded PHY, Core 5.1
LL/TIM/SLA/BV-01-C
Test that a slave IUT on accepting a parameter update from the master
adopts a new anchor point when starting to use the new parameters
LL/TIM/SLA/BV-02-C
Test that the slave IUT is able to establish and maintain a connection with a
master that uses the earliest possible timing for the first transmission
LL/TIM/SLA/BV-03-C
Test that the slave IUT is able to establish a connection with a master that
uses the latest possible timing for the first transmission
LL/TIM/SLA/BV-04-C
SLAVE - Packets To Another Slave
LL/TIM/SLA/BV-05-C
SLAVE - Packets To Another Slave
LL/TIM/SLA/BV-06-C
Earliest Transmission to Slave
LL/TIM/SLA/BV-07-C
Latest Transmission to Slave
LL/TIM/SLA/BV-08-C
Initiate Sleep Clock Accuracy Update
LL/TIM/SLA/BV-09-C
Response to Sleep Clock Accuracy Update
LL/TIM/SLA/BV-10-C
Response without Reducing the Sleep Clock Accuracy
4.1.3 Importing Tests
If the SIG’s Bluetooth Launch Studio (BLS) was used to generate the BLS document with a list of tests,
the BLS document can be imported into Harmony to automatically select the tests.
To import the tests:
1.
Click “Import/Export”
2.
Click “Import test selection from Bluetooth Launch Studio document…”
3.
Point to the location of the file
4.
Open the file. (Figure 4.2)
Summary of Contents for FrontLine Harmony
Page 1: ...Harmony Test System User Manual...
Page 7: ...Frontline Harmony Hardware Software User Manual 7 Figure 1 1 Installed Applications Detected...
Page 25: ...Frontline Harmony Hardware Software User Manual 25 Figure 3 5 IUT Information...
Page 55: ...Frontline Harmony Hardware Software User Manual 55 Figure 5 4 Testing Summary...