Frontline Harmony Hardware & Software User Manual
23
Figure 3.3 – Tester and IUT Configuration
1.
If the Harmony hardware is connected, the BD ADDR of the Harmony and the port that the
Harmony is connected to will be displayed.
2.
Connect the IUT.
3.
Under IUT Configuration, set Device Type to Generic UART.
4.
The BD ADDR of the IUT will remain blank until testing is started. Once testing has started
the BD ADDR for the IUT will be filled in automatically.
5.
Select the correct PORT for the IUT to enable a connection to the IUT.
6.
Select the correct Baud Rate for the IUT.
7.
Select the correct Flow Control for the IUT.
8.
Select the preferred method for resetting the IUT between test cases:
a.
HCI Reset – this setting will allow the Harmony tester to send an HCI reset command
to the IUT
b.
Power Cycle – this setting will allow the Harmony tester to shut off power to the
USB port and toggle the relay for a configurable number of seconds. Note: The “Off
Seconds” textbox will be enabled when “Power Cycle” is selected.
9.
Click the “IUT Supported Commands” button to populate the octet fields. Note: It is
important to fill in the octet fields otherwise some tests will fail.