Frontline Harmony Hardware & Software User Manual
32
LL/CON/MAS/BV-44-C
Test that a master IUT is able to respond to a PHY update procedure from a
slave device when asymmetric links are not supported
LL/CON/MAS/BV-45-C
Test that a master IUT is able to perform the PHY update procedure when
there is a procedure collision between the IUT's PHY change request and
the remote device's PHY change request
LL/CON/MAS/BV-46-C
Test that a master IUT terminates the Link Layer connection if the master-
initiated PHY update procedure is not completed before the procedure
response timer expires
LL/CON/MAS/BV-47-C
Test that a master IUT is able to perform the channel map update
procedure when there is a procedure collision between the IUT's channel
map update and the Lower Tester's PHY change request
LL/CON/MAS/BV-48-C
Test that a master IUT is able to perform the connection parameters
request procedure when there is a procedure collision between the IUT's
connection parameters request and the Lower Tester's PHY change request
LL/CON/MAS/BV-49-C
Test that a master IUT follows all packet time restrictions both during and
after PHY change when it initiates the PHY update procedure
LL/CON/MAS/BV-50-C
Test that a master IUT both during and after PHY change follows all packet
time restrictions when it responds to a PHY update procedure from a slave
device
LL/CON/MAS/BV-51-C
Test that a master IUT correctly handles the case where it initiates a PHY
update procedure but no common PHYs are available
LL/CON/MAS/BV-52-C
Test that a master IUT is able to receive data from a slave device when the
slave is transitioning between 125kbit and 500kbit coded rates. Confirm
that IUT responds within the allowed T_IFS times for each packet at either
coded rate. Test is performed with the IUT's minimum and maximum
supported packet length. A Data Length Update Procedure is performed if
required
LL/CON/MAS/BV-53-C
Test that a master IUT follows all packet time restrictions both during and
after PHY update when it initiates the PHY Update Procedure. In particular
test that the IUT does not queue a packet for transmission that would
satisfy the requirements when queued but violate them if it is still waiting
for retransmission after the PHY Update instant
LL/CON/MAS/BV-54-C
Test that a master IUT both during and after PHY update when it responds
to a PHY Update Procedure from a slave device. In particular test that the
IUT does not queue a packet for transmission that would satisfy the
requirements when queued but violate them if it is still waiting for
retransmission after the PHY Update instant
LL/CON/MAS/BV-55-C
Test that a master IUT still transmits data even when the TxTime and/or
RxTime values for LE Coded PHY suggest a smaller possible data length than
the minimum length data PDU (27 octets)
LL/CON/MAS/BV-56-C
Constant Tone Extension Request Procedure, IUT Initiated, AoA – LE 1M
PHY
LL/CON/MAS/BV-57-C
Constant Tone Extension Request Procedure, IUT Initiated, Periodic
LL/CON/MAS/BV-58-C
Constant Tone Extension Request Procedure, IUT Initiated, Responses
Disabled
LL/CON/MAS/BV-59-C
Verifies that the IUT correctly handles the case where the remote does not
support the Connection CTE Response feature.
Summary of Contents for FrontLine Harmony
Page 1: ...Harmony Test System User Manual...
Page 7: ...Frontline Harmony Hardware Software User Manual 7 Figure 1 1 Installed Applications Detected...
Page 25: ...Frontline Harmony Hardware Software User Manual 25 Figure 3 5 IUT Information...
Page 55: ...Frontline Harmony Hardware Software User Manual 55 Figure 5 4 Testing Summary...