![Teldat Dm709-I User Manual Download Page 37](http://html1.mh-extra.com/html/teldat/dm709-i/dm709-i_user-manual_1079560037.webp)
n2-max-retry
Max retry value
n3-frames_rcvd-before-ack
Rcvd I-frames before ack
no
Negates a command or sets its defaults
nw-acks-to-inc-ww
Acks needed to increment Ww
rw-receive-window
Receive window
t1-reply-timer
Reply timer
t2-receive-ack-timer
Receive Ack timer (in 100 millisec.)
ti-inactivity-timer
Inactivity timer
tw-transmit-window
Transmit window
exit
ethernet0/0 LLC config>
5.3.2 LIST
Displays the current LLC configuration.
Syntax:
ethernetX/X LLC config>list
Example:
ethernet0/0 LLC config>list
No LLC configuration record found for this interface.
Default values are used.
Reply Timer(T1):
1 seconds
Receive ACK Timer(T2):
1 100miliseconds
Inactivity Timer(Ti):
30 seconds
Max Retry value(N2):
8
Rcvd I-frames before Ack(N3):
1
Transmit Window(Tw):
2
Receive Window(Rw):
2
Acks needed to increment Ww(Nw): 1
ethernet0/0 LLC config>
5.3.3 N2-MAX-RETRY
Maximum number of times LLC transmits an RR without receiving an acknowledgment when the inactivity timer
times out. Values can range from 1 to 255. Default is 8.
Syntax:
ethernetX/X LLC config>n2-max-retry <valor>
Example:
ethernet0/0 LLC config>n2-max-retry 8
ethernet0/0 LLC config>
5.3.4 N3-FRAMES_RCVD-BEFORE-ACK
This counter works with the T2 timer to reduce acknowledgment traffic for I-frames received. Each time the router re-
ceives an I-frame, this value decreases by one. When this counter reaches 0, or when the T2 timer times out, the
router sends an acknowledgement. Values range from 1 to 255. Default is 1.
Syntax:
ethernetX/X LLC config>n3-frames_rcvd-before-ack <valor>
Example:
ethernet0/0 LLC config>n3-frames_rcvd-before-ack 1
ethernet0/0 LLC config>
5.3.5 NO
Sets the different parameters to their default values.
Syntax:
Teldat SA
5 LLC Configuration
LAN Interfaces
31