elmeg DECT200 Multicell System / en / elmegDECT200M_en / starting.fm / 18.10.2013
V
e
rsion 1, 01.0
7
.2012
15
elmeg DECT200 Multicell System
bintec elmeg
First steps
Preparing to use the telephone system
To start using your elmeg DECT200 Multicell System, you must now perform the following
steps:
u
Register base stations to the telephone system and synchronise them
u
Register handsets to the telephone system, configure and assign VoIP accounts
Registering base stations to the DECT Manager
Before starting to register the base stations, please ensure that you have the installation plans
available, which you created during the planning phase of your DECT network.
You need the
MAC address
of the installed base stations and the following planning data:
u
Name, location
You can select any name for the base station. This should contain its location, to enable the
relevant elmeg DECT200 to be found quickly for maintenance purposes.
u
Synchronisation level
Base stations that combine to form a DECT wireless network must synchronise with one
another to ensure a smooth transition of the handsets from cell to cell (handover).
As a base station in a multicell DECT network often has an inadequate connection to some
of the other base stations, you must set up a synchronisation hierarchy.
Detailed information about synchronisation planning can be found in "Gigaset N720 DECT
IP Multicell System - Site Planning and Measurement Guide".
u
Cluster structure
Groups of base stations that are a long way apart must be assigned to different clusters.
To register the base stations, set up clusters and define the synchronisation hierarchy, please
use the Web configurator on the DECT Manager. This is described in Section
Please note
For detailed information on setting up the elmeg DECT200 Multicell System on a PABX of the
hybird family please refer to the „elmeg DECT150 startup“ leaflet delivered separately.
Please note
Synchronisation always refers to a cluster. You can set up several clusters that are not
synchronised with one another, so there is no possibility of a handover between clusters.
Summary of Contents for BinTec Elmeg DECT200
Page 3: ......