Removal and Replacement
4- 28
WFM6100, WFM7000, and WFM7100 With Option FP Service Manual
The rear panel is formed by the chassis and by the individual module rear panels,
which overlap and are bolted together (see Figure 4--4).
Audio
EYE/PHY
Composite
Figure 4- 4: Module securing screws
The Composite board, if installed, is located in the right module bay (see
Figure 4--4).
1.
Remove the four T-15 screws securing the Composite module to the rear
panel.
2.
Lift the Composite module out of the instrument, rocking it gently until the
connector separates from J13 on the Main board. It may help to loosen the
three screws that hold the EYE/PHY rear panel (or blank).
The Mezzanine board, if installed, is located below the right module bay.
1.
Remove the nuts securing the three SDI BNC connectors in the lower right
corner of the rear panel.
2.
Disconnect the ribbon cable from J4 on the Mezzanine board.
NOTE
. Do not pull on the ribbon cable. Grip the body of the connector, or pry
the connector away from the plug with a small screwdriver.
Rear panel
Composite board
(Option CPS)
Mezzanine board
Summary of Contents for WFM6100 Opt. MB