Removal and Replacement
4- 32
WFM6100, WFM7000, and WFM7100 With Option FP Service Manual
Front Panel screws
Bezel securing clips
Bezel securing screws
Figure 4- 6: Front panel disassembly
LCD backlight.
You must separate the LCD assembly from the frame to change
the LCD backlights.
7.
Disconnect the two backlight cables from the Inverter board.
8.
Remove the four T-10 screws securing the LCD assembly to the frame.
9.
Pull the LCD assembly away from the frame, taking note of the routing of
the backlight cables.
10.
Remove each of the backlight tubes by pressing down on the clip
(see figure 5--2, on page 5--7) and pulling it from the LCD assembly.
NOTE
. Avoid touching the LCD backlight tube. Oil from the fingers can cause
hot spots and premature failure. If you do touch the backlight tube, clean it with
isopropyl alcohol before reinserting the tube into the instrument.
11.
When reassembling, make sure to route the backlight cables as noted in
step 9, behind the Front Panel standoffs and clear of the cutout for the
USB/Headphone connectors.