Specifications
TLA600 Series Logic Analyzer Service Manual
1- 7
Table 1- 5: TLA600 clocking (Cont.)
Characteristic
Description
Clocking state machine
Pipeline delays
Each channel group can be programmed with a pipeline delay of 0 through 3 active
clock edges.
1
It is possible to use storage control and only store data when it has changed (transitional storage).
2
Applies to asynchronous clocking only. Setup and hold window specification applies to synchronous clocking only.
3
Any or all of the clock channels may be enabled. For an enabled clock channel, either the rising, falling, or both edges
can be selected as the active clock edges. The clock channels are stored.
4
Full and half speed modes are controlled by PowerFlex options and upgrade kits.
5
All qualifier channels are stored. For custom clocking there are an additional 4 qualifier channels on C2 3:0 regardless of
channel width.
Table 1- 6: TLA600 trigger system
Characteristic
Description
Triggering resources
Word/Range recognizers
16 word recognizers. The word recognizers can be combined to form full width, double
bounded, range recognizers. The following selections are available:
16 word recognizers
0 range recognizers
13 word recognizers
1 range recognizer
10 word recognizers
2 range recognizers
7 word recognizers
3 range recognizers
4 word recognizers
4 range recognizers
Range recognizer channel order
From most-significant probe group to least-significant probe group: C3 C2 C1 C0 E3
E2 E1 E0 A3 A2 D3 D2 A1 A0 D1 D0 Q3 Q2 Q1 Q0 CK3 CK2 CK1 CK0
Missing channels for modules with fewer than 136 channels are omitted.
Glitch detector
1,2
Each channel group can be enabled to detect a glitch
Minimum detectable glitch pulse width
(Typical)
2.0 ns (single channel with P6417, P6418, or a P6434 probe)
Setup and hold violation detector
1,3
Each channel group can be enabled to detect a setup and hold violation. The range is
from 8 ns before the clock edge to 8 ns after the clock edge. The range can be
selected in 0.5 ns increments.
The setup and hold violation of each window can be individually programmed.
Transition detector
1
Each channel group can be enabled or disabled to detect a transition between the
current valid data sample and the previous valid data sample.
This mode can be used to create transitional storage selections where all channels
are enabled.
Summary of Contents for TLA600 Series
Page 5: ......
Page 13: ...Table of Contents viii TLA600 Series Logic Analyzer Service Manual...
Page 17: ...Service Safety Summary xii TLA600 Series Logic Analyzer Service Manual...
Page 51: ...Theory of Operation 3 4 TLA600 Series Logic Analyzer Service Manual...
Page 89: ......
Page 97: ...TLA600 Adjustment Procedures 5 8 TLA600 Series Logic Analyzer Service Manual...
Page 113: ...Maintenance 6 4 TLA600 Series Logic Analyzer Service Manual...
Page 157: ...Repackaging Instructions 6 48 TLA600 Series Logic Analyzer Service Manual...
Page 159: ...Options 7 2 TLA600 Series Logic Analyzer Service Manual...
Page 161: ...Electrical Parts List 8 2 TLA600 Series Logic Analyzer Service Manual...
Page 165: ...Diagrams 9 4 TLA600 Series Logic Analyzer Service Manual...
Page 176: ...Mechanical Parts List TLA600 Series Logic Analyzer Service Manual 10 11...
Page 185: ...Mechanical Parts List 10 20 TLA600 Series Logic Analyzer Service Manual...
Page 186: ......
Page 187: ......