Reference
Table 36.Error Code descriptions (cont.)
Utilities
E701
Number of edges found in the
waveform is less than required
edges (user input) to perform the
deskew operation
Before the deskew operation can
start, the edge(s) available for
deskew operation must be greater
than or equal to the number of
edges needed
Adjust the timebase and (or) increase the
record length. Perform the deskew operation
by entering less number of edges
E702
Propagation delay is more than
one cycle
The deskew operation is performed
on the same signal source. Check
whether dissimilar signals or any
external sources (like different
probes) are used
Check whether the same signal source is
used for the "From" and "To" channels.
Check whether the bandwidth of the probes
is sufficient for the signal bandwidth
E701
Number of edges found in the
waveform is less than required
edges (user input) to perform the
deskew operation
Before starting the deskew
operation, the application tries to
find out if the edge(s) available for
deskew operation is greater than or
equal to the number of edges
needed
Adjust the timebase and (or) increase the
record length. Perform the deskew operation
by entering less number of edges
E702
Propagation delay is more than
one cycle
The deskew operation is performed
on the same signal source. Check
whether dissimilar signals or any
external sources (like different
probes) are used
Check whether the same signal source is
used for the "From" and "To" channels.
Check whether the bandwidth of the probes
is sufficient for the signal bandwidth
TSV File Generator
E721
Error in generating a .tsv file
This message is generated if there
is an error while generating the .tsv
file for the given inputs
Check the correctness of the input .csv file(s)
and the output .tsv file
E722
Timestamp of the two .csv files
did not match. Conversion failed
There will be two separate .csv files,
one for D+ and another for D-. Each
of these files consists of the time
values of the D+ and D- signal. It is
expected that both the files should
have Data at same time stamp
Try generating the .tsv file with a new set of
.csv files
E725
Invalid CSV file format
This happens if the user does not
use a valid CSV file format for the
CSV-TSV file conversion
Check whether the CSV files are generated
using the supported instruments and ensure
that "Include waveform scale factors" is
selected while generating a CSV file
E723
.csv file(s) not found
The .csv file(s) are needed for the
.csv source mode selection is not
found. Two valid .csv files are
needed for the Single-ended signals
and one valid .csv file is needed for
Differential signals
Check that the extension of the file(s) is .csv.
Make sure to press the Enter key while
entering the file name in the file selection
field to update old file names
E724
tsv file not found
A valid .tsv file is needed as
destination file
Make sure to press the Enter key while
entering the file name in the file selection
field to update old file names. Enter the .tsv
extension while entering the file name
170
TDSUSB2 Universal Serial Bus Measurement Package
Summary of Contents for TDS5032
Page 1: ...TDSUSB2 Universal Serial Bus Measurement Package 077 0015 04 www tektronix com...
Page 12: ......
Page 24: ...Getting Started 10 TDSUSB2 Universal Serial Bus Measurement Package...
Page 32: ...Installation 18 TDSUSB2 Universal Serial Bus Measurement Package...
Page 61: ...Operating Basics TDSUSB2 Universal Serial Bus Measurement Package 47...
Page 76: ...Taking Measurements 62 TDSUSB2 Universal Serial Bus Measurement Package...
Page 88: ...Tutorial 74 TDSUSB2 Universal Serial Bus Measurement Package...
Page 158: ...Application Examples 144 TDSUSB2 Universal Serial Bus Measurement Package...
Page 228: ...Measurement Algorithms 214 TDSUSB2 Universal Serial Bus Measurement Package...
Page 248: ...Glossary 234 TDSUSB2 Universal Serial Bus Measurement Package...