Timing Parameters
1-46
DTG5078 & DTG5274 & DTG5334 Data Timing Generator User Manual 2
Restrictions on using
External Clock and PLL
Input
If you use either External Clock or External PLL Input, the user-defined clock
frequency setting is restricted as below, depending on the frequency of the external
input signal, use of Long Delay, and the data format condition.
Table 1-10, “Restrictions on using External Clock Input” summarizes the
restrictions that arise when you select External Clock Input for the clock source.
Table 1-11, “Restrictions on using External PLL Input” on page 1-47 summarizes
the restrictions that arise when you select External PLL Input.
Table 1-10: Restrictions on using External Clock Input
External Clock
Frequency
Data Generator mode
Long Delay ON
Data Generator mode
Long Delay OFF
Pulse Generator mode
NRZ only
includes RZ or R1
Fextcl <
400 MHz
Error. (The sequence cannot start.)
As an external clock signal,
you can input the signal of
the frequency range of
following Fextcl.
Fextcl =1 MHz to 750 MHz
(DTG5078)
Fextcl =1 MHz to 2.7 GHz
(DTG5274)
Fextcl =1 MHz to 3.35 GHz
(DTG5334)
The clock frequency is
fixed to
Fextcl (NRZ only), or
Fextcl / 2 (includes RZ or
R1)
according to the Fextcl.
Error. (The sequence
cannot start.)
400 MHz
Fextcl
800 MHz
You can change the clock range. The vector rate is
uniquely determined according to the change of the clock
range, resulting in a fixed clock frequency of Fextcl /
Vector Rate.
You can not select the
clock range, but DTG5000
selects it automatically.
The vector rate is uniquely
determined according to the
change of the clock range,
resulting in a fixed clock
frequency of Fextcl /
VectorRate.
800 MHz < Fextcl The clock range is fixed to
400 MHz or more. The
vector rate is 1, while the
clock frequency is fixed to
Fextcl.
The clock range is fixed to
200 MHz or more. The
vector rate is 2, while the
clock frequency is fixed to
Fextcl / 2.
The internal clock range is
fixed to 200 MHz or more.
The vector rate is 2, while
the clock frequency is fixed
to Fextcl / 2.
≤
≤
Summary of Contents for DTG5078
Page 4: ......
Page 10: ...Table of Contents iv DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 19: ...Reference...
Page 20: ......
Page 24: ...Operating Modes 1 4 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 34: ...Data Structure 1 14 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 58: ...Pattern Edit 1 38 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 88: ...Timing Parameters 1 68 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 100: ...DC Output 1 80 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 120: ...Jitter Generation 1 100 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 146: ...Pulse Generator mode 1 126 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 150: ...Offline mode 1 130 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 176: ...Diagnostics and Calibration 1 156 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 177: ...Appendices...
Page 178: ......
Page 186: ...Appendix B System Recovery B 4 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...
Page 189: ...Index...
Page 190: ......
Page 196: ...Index Index 6 DTG5078 DTG5274 DTG5334 Data Timing Generator User Manual 2...