Maintenance-5110
3.
Mount
the stationary slide-out
sections to the rear
rack
rails using either of these methods.
(a)
If the rear rail holes are not
tapped to accept 10-
32
machine screws,
mount the left stationary section
with
hardware provided as shown in the left or center
illustration of
Fig. 4-2A. Note that the rear mounting
bracket
can be installed either way so the slide-out
tracks will
fit a
deep or
shallow cabinet rack. Use Fig. 4-
2A as a guide for mounting
the right stationary section.
Make
sure that
the
stationary
sections are horizontally
aligned so
they are level
and parallel with each other.
(b) If the rear rack rail holes are tapped to accept 10-
32
machine
screws, mount the
left stationary section
with
hardware provided as
shown
In the left or center
illustration of
Fig. 4-2B.
Note that the rear mounting
bracket
can be installed either way so the slide-out
tracks
will
fit a deep or shallow cabinet rack stationary
section.
Make
sure the stationary
sections are horizon
tally aligned
so they are level and parallel with each
other.
To
secure the instrument front-panel
to the rack, the
rack
must
either have
universal
hole spacing, or a hole
must be drilled and tapped for a 10-32 screw, see
Fig. 4-3.
Using the
hardware (not furnished)
indicated in Fig. 4-3,
secure
the instrument to the front rails of the
rack.
Slide-Out
Track Maintenance
The
slide-out
tracks require no lubrication. Thespeciai
dark gray finish
on
the
sliding parts is a permanent
lubrication.
Ventilation
Requirements
When
the
oscilloscope is mounted in a
rack
with other
equipment,
it
is important that the ambient temperature
surrounding
it does not
50° C. Additional
clearance
or forced
ventilation methods (fan) may
need to
be
employed
to maintain ambient
temperatures below
+50°C.
Reliability and
performance of
the oscilloscope
will
be affected
if the ventilation holes in the protective
panels
are
obstructed, or if
it is
operated at an ambient
temperature
higher
than
-I5O°C.
Installation
And Adjustment
To
insert the instrument into the rack, proceed as
follows:
1.
Pull the slide-out track intermediate sections
out
to
the fully extended position.
2.
Insert
the
instrument chassis sections into the
intermediate
sections.
3.
Press
the stop latches on the chassis
sections
and
push
the instrument toward the rack until the latches
snap
into
their
holes.
4.
Again press the
stop latches and push the instru
ment into the rack.
To adjust the slide-out tracks for
smooth sliding action,
loosen the screws used to join the stationary
sections to
the rails of the rack.
Center the
instrument, allowing the
slide-out
tracks
to seek
the
proper
width, then tighten the
screws.
REPACKAGING FOR
RESHIPMENT
If
the Tektronix
instrument is to be shipped to a
Tektronix
Service
Center
for service or repair, attach a
tag
showing: owner
(with address) and the name of an
individual
at your
firm that can be contacted. Include
complete instrument serial number and a
description of
the service
required.
Save
and re-use
the package in
which your
instrument
was
shipped.
If the original packaging is unfit for
use or
not available, repackage
the instrument as follows:
Surround the instrument
with polyethylene sheeting
to
protect the finish
of the instrument. Obtain a
carton of
corrugated
cardboard of the correct carton
strength
and having inside dimensions of no less
than
six
inches more
than the
instrument dimen
sions.
Cushion the
instrument by tightly packing
three inches
of dunnage or
urethane
foam between
carton and instrument,
on all sides. Seal carton
with
shipping tape or industrial stapler.
The
carton
test
strength for your instrument is 275
pounds.
4-6
Summary of Contents for 5110
Page 6: ...5110 Fig 1 1 5110 Oscilloscope 2134 01 ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 83: ...5110 I43XII3 2134 15 ...
Page 84: ... i 143 I132 2134 15 BLOCK DIAGRAM ...
Page 85: ... t 2 E I 5110 S LNHNOdWOD BOVJHaiNI ...
Page 88: ...J4 O3 INTERFACE J INTERFACE A NOV 1978 ...
Page 92: ...AUXILIARY BOARD 1143 2134 18 AUXILIARY BOARD ...
Page 95: ...DEFLECTION AMPLIFIERs ...
Page 102: ...LV POWERSUPPLY CALIB COMPONENTS A 4 L V Power Supply circuit board 5110 ...
Page 107: ...SIGNALS OUT OPTION 7 ONLY SI 10 OPT 7 213 26 REV A FE BI979 SIGNALS OUT COPTION T ONLY n ...
Page 114: ......
Page 115: ...5110 OSCILLOSCOPE ...
Page 116: ...FIG 2 MAINFRAME p 5110 OSCILLOSCOPE ...
Page 117: ...1 ...
Page 121: ...o ...
Page 122: ...S 1 5110 OSCILLOSCOPE ...
Page 123: ...13 FIG 4 RACKMOUNT CABINET 5110 OSCILLOSCOPE ...
Page 124: ......