Operator Checks and Adjustments
Horizontal C ontrols
MODE
A
POSITION
Center the trace
X I 0 MAG
Off
A SEC/DIV
0.1 ms
SEC/DIV VAR
Calibrated detent
Trigger C ontrols
HOLDOFF
MIN
A/B SELECT
A
MODE
AUTO LEVEL
SOURCE
VERT
CPLG
DC
Display
A INTEN
Desired brightness
FOCUS
Best trace definitior
READOUT
Desired brightness
SCALE ILLUM
Desired brightness
MENU System C ontrols
MEASUREMENT MODES,
AH off (Press
TRACKING CURSORS,
CLEAR DISPLAY
MENUS and
three times to
STORE/RECALL
ensure all off.}
Auto Setup Function
The Auto Setup function can be used to automatically set up the front-panel
controls to produce a usable display of the applied signal.
1.
Connect signal(s) to be displayed to the appropriate input connector(s).
For triggering to be set up properly when the AUTO SETUP button is
pressed, connect the trigger-source signal to the lowest numbered
channel that will be turned on.