TV SIGNAL DISPLAYS
Displaying a TV Line-rate Signal
1. Perform the steps and set the controls as outlined
under Baseline Trace and Signal Display to obtain a basic
display of the desired TV signal.
2. Set A SEC/DIV to 10 Ms, and A & B INT to CH 1 or
CH 2 as appropriate for applied signal.
3. Set A TRIGGER SLOPE for a positive-going signal
(lever up) if the applied TV signal sync pulses are positive
going, or for a negative-going signal (lever down) if the TV
sync pulses are negative-going.
4. Adjust the A TRIGGER LEVER control for a stable
display, and AUTO INTENSITY for desired display bright
ness. If necessary, adjust VERTICAL VOLTS/DIV control to
obtain 5 divisions or greater amplitude for a stable display.
Operating Instructions— 2213 Service
Displaying a TV Field-rate Signal
1. Perform Step 1 under Displaying a TV Line-rate
Signal.
2. Set A SEC/DIV to 2 ms, A TRIGGER MODE to TV
FIELD and A & B INT to CH 1 or CH 2 as appropriate for
the applied signal.
3. Perform Step 3 and 4 under Displaying a TV Line-rate
Signal.
4. To display either Field 1 or Field 2 individually at faster
sweep rates (displays of less than one full field), set VERTI
CAL MODE to BOTH and ALT simultaneously. This syn
chronizes the Channel 1 display to one field and the
Channel 2 display to the other field.
To change the field that is displayed, interrupt the triggering
by repeatedly setting the AC GND DC switch to GND or dis
connecting the signal from the applied signal input until the
other field is displayed. To display both fields simultaneous
ly, apply the input signal to both the CH 1 and CH 2 inputs
via two probes, two cables, or through a dual-input coupler.
To examine either a TV Field-rate or Line-rate signal in more
detail, either the X I0 Magnifier or HORIZONTAL MODE
functions may be employed as described for other signals
elsewhere in this manual.
@ NOV 1981
2-11
Summary of Contents for 2213
Page 1: ...Ttektronix 2213 OSCILLOSCOPE SERVICE IN S T R U C T IO N M A N U A L ...
Page 9: ...2213 Service 3827 01 viii The 2213 Oscilloscope ...
Page 30: ...Theory of Operation 2213 Service 3 3 Figure 3 1 Basic block diagram of the 2213 Oscilloscope ...
Page 67: ...Adjustment Procedure 2213 Service 5 2 ...
Page 139: ...Figure 9 4 2213 block diagram S105 ...
Page 140: ...a o m 7 x C O o z CHANNEL SWITCH AND VERTICAL OUTPUT ...
Page 141: ...2213 Service ...
Page 144: ...2213 ...
Page 146: ...2213 3827 20 R V FB 4982 C 4 ...
Page 147: ...S90I 4 5 ...
Page 148: ...CIRCUIT BOARD INTERCONNECTIONS K tv ra n m CIRCUIT BO ARD IN T E R C O N N E C T IO N S ...
Page 151: ......
Page 153: ...2213 3 K T i RtV D E C ...
Page 154: ......
Page 155: ...2213 Service 1 3 a 7 ...
Page 161: ...2213 Service n 3 a ...
Page 168: ...s RE 2213 ...
Page 169: ... CH 1 CH 2 VERTICAL PREAMPS ...
Page 175: ......
Page 177: ...TRIGGER ...
Page 180: ...fr ...
Page 181: ...f E V AUG I98Z SWEEP GENERATOR LOGIC ...
Page 184: ......
Page 188: ...2 2 1 3 lAlO FWTW m ain b o a rd ...
Page 190: ...i _____H M N XY AMPLIFIER HORIZ OUTPUT ...
Page 191: ...A 1 1 C 1 a i F 1 G 1 H 1 3 4 5 6 7 HO COM TO P 4 C C O 5 S I i S2T 2e R EV Dec I9BI 2 2 3 ...
Page 203: ...2 2 1 3 Service R887 ASTIG R870 GEOM C784 5ns TIMING R860 GRID BIAS ...
Page 207: ... ...
Page 216: ...I ...
Page 217: ...2213 OSCILLOSCOPE ...
Page 218: ......
Page 219: ...2213 OSrs ...
Page 225: ......