![TekTone Tek-CARE 550 Installation And Operation Manual Download Page 46](http://html1.mh-extra.com/html/tektone/tek-care-550/tek-care-550_installation-and-operation-manual_1077333046.webp)
System Customization
set up earlier in the Config Tool.
Add Facility Staff
Skip this step if the facility does not require the use of paging or email communication.
In this step, staff members will be added to the system and assigned to pagers or email
addresses. Pagers and email address were added to the system in
Step 11
of
System
Installation and Setup.
Add Facility Staff in the Event Monitor
1. In the Event Monitor software, click the
Registers
button and then select
Staff
from the page selection list.
2. To add a new staff member, click the
Add (+)
button to unlock the
Details
editing
pane. Type the staff member’s name in the
Name
:
field, select the correct type
(if any) from the
Staff Type
:
drop-down menu, and check the
Active
:
box to
enable the staff member.
3. Check the boxes in the
Paging
and
Email Address
lists for which pager(s) and
email address(es) to associate with the new staff member. If the staff member
is to be assigned to one or more home zones, check the appropriate boxes in
the
Home Zones
list as well. If the staff member is to be assigned to all zones,
leave all zones checked.
4. Click
Apply
to add the new staff member.
Add Facility Staff in the Config Tool
1.
With the Event Monitor software running, open the Config Tool software. When
prompted, choose
Load Configuration from System
on the splash screen.
If the Config Tool is already running, choose
File>Load Configuration from
System
to ensure that the most current system configuration is open for editing.
2. Choose
Staff
from the page selection pane.
3. To add a new staff member, click the
Add (+)
button to unlock the
Details
editing
pane. Type the staff member’s name in the
Name
:
field, select the correct type
(if any) from the
Staff Type
:
drop-down menu, and check the
Active
:
box to
enable the staff member.
4. Check the boxes in the
Paging
and
Email Address
lists for which pager(s) and
email address(es) to associate with the new staff member. If the staff member
is to be assigned to one or more home zones, check the appropriate boxes in
the
Home Zones
list as well. If the staff member is to be assigned to all zones,
leave all zones checked.
5. Click
Apply
to add the new staff member to the system.
38 • IL948 Tek-CARE
®
500 & Tek-CARE
®
550 Installation Manual