ENGLISH
TEKNO POINT ITALIA S.R.L. - VIA DELL’ARTIGIANATO 5 - 30020 MARCON (VE) – ITALY
MUI_CAIO_Ita_Eng_Fra_TP/Rev.06/Data 21.02.2022
87
Bottom view of the unit
1.Remove the fixing platescrews.
Front view of the unit
2.Remove the sealplate.
Front view of the unit
3.Pull down the filter screen to removeit.
REFRIGERANT CHARGE (notapplicable to M version)
The unitissupplied with the appropriate charge for itscorrectoperation.
However, if the unitneeds to be charged for anyreason, the following instructions must be followed:
- Carefully check the cause of the refrigerant leak and repair the leak.
- Use the specificrefrigerant filling equipment for R32. Ensurethatdifferenttypes of refrigerant do not
contaminate eachother.
- The refrigerant tank must be helduprightwhen filling with refrigerant.
- Affix the charge label on the unit after filling (evenif the chargewaspartial).
- Do notovercharge the unit.
- After charging, carry out a thorough check for leaks beforestarting the unit; a second check for leaks must
be carried out after switching on.
Filter
Pus hit down
Remove the door