24
V
E R S I O N
1 . 4 2
/
A
U G U S T
2 6 ,
2 0 0 5
S
TEP
4:
S
ET UP THE
24VDC
P
OWER
D
ISTRIBUTION
The eF-785 features a configurable 24VDC distribution system designed
to manage power control to a wide range of low voltage devices
including:
•
Solenoids
•
Proximity Sensors
•
Solenoid valves
•
Slotted optical sensors
•
Contactors
•
Signal conditioning modules
•
Relays
•
Gas valves
•
Indicator lamps
•
Buzzers
•
Through-beam sensors
•
Hall Effect sensors
•
Small stepper drives
•
Many others
115V
J
A
Host Power
J
B
Host Power
P3
Main
AC Motor Power
Load
AC Motor Power
J4
S
A
F1, F2 Host Pwr. 8A Max
P12
Safety Harness
Hazardous
AC Out
J2
P14
P13
Safety Control Ext.
DC Motor Supply
48-90VDC
24VDC
Supplies
J5
P6
USB
P15
P16
Main DC Motor Pwr.
90VDC Max.
P7A
P7B
P18
40V
100-125/200-240
VAC~ 20A, 50-60Hz
P9 A,B
24VDC
Ckt. 1
P10 A,B
24VDC
Ckt. 2
J8A
J8B
Option DC Motor Pwr.
90VDC Max.
P11 A,B
24VDC
Ckt. 3
Net Out
Net In
RED
BLK
P2
IEEE-1284 Host Port
J17
24VDC POWER SUPPLY
CONNECTOR (J5)
24VDC OUTPUTS
(
P9
A,B
P10
A,B
P11
A,B)
24VDC Distribution Connectors
S
ELECTING THE
P
OWER
S
UPPLIES
Your 24VDC power distribution requirements will help you determine
which power supply (or supplies) and wiring harness to select. You can
integrate 1 or 2 supplies depending on your machine’s specific
requirements.
There are a few considerations to keep in mind when selecting the
24VDC supply/supplies to be used with the eF-785. The supply you
choose should, at a minimum have:
•
•
•
Internal protective fusing
A nominal voltage range of 12-41VDC
Output current not to exceed 20A Maximum
C
ONNECTING
24VDC
P
OWER SUPPLIES
(J5)
The 24VDC supplies are connected to the 24VDC Supply connector J5
(see figure below), located on the rear panel of the eF-785. This
connector not only serves to provide two different control modes for AC
line voltage to power the supplies (described below), it also receives the
24VDC power back from the supplies for fusing and external distribution.
Summary of Contents for EF-785
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Page 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Page 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Page 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Page 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Page 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Page 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Page 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Page 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...