Daisy-chained loop wiring topology
•
Central star
This wiring method may be required when the 24V
circuits within the powered devices are electrically connected to
the chassis or other control circuits to reduce noise. The central
star distribution method will prevent ground loops in the machine
from occurring. In this method, each load is wired individually to
the eF-785 by using a terminal block or distribution panel to bring
power to each load separately.
Central star wiring topology