This section provides a brief review of the two “Supplementary Options”,
Host Soft Shutdown, and Post E-stop Enable, and describes how to
change these options, by setting the appropriate eF-785 internal jumpers.
H
OST
S
OFT
S
HUTDOWN
When
enabled
, the Soft Shutdown feature allows you to power off your
machine by shutting down the host computer. When Soft Shutdown is
disabled
, you must power down the host PC and the eF-785 separately.
See the Supplementary Options section for more details.
P
OST
E-S
TOP
E
NABLE
When
enabled
, the Post E-Stop Enable feature requires that the operator
not only reset the e-stop switch, but also press the on/enable button to
restore hazardous power availability to the machine after an Emergency
Stop (E-Stop) has occurred. When this feature is
disabled
, hazardous
power can become available as soon as the E-Stop button is reset to its
normal operating position. See the Supplementary Options section for
more details.
C
HANGING THE
J
UMPER
S
ETTINGS
Step 1: Remove all power from the eF-785.
Step 2: Remove the top access panel. Refer to diagram below.
F6
24VDC Ckt. 3
10A Max.
40VDC
ControlPoint
TM
24VDC
Safety
F7
F8
F10
F9
DC Servo Main
15A Max.
DC Servo Option
15A Max.
CB2
CB3
Status
24VDC Ckt. 2
10A Max.
24VDC Ckt. 1
10A Max.
SAFETY ALARM
Do not operate or service
machine if sounding
eFoundation- Power Distribution & Safety Control Center
CB1, UL489 Rated Input Breaker
10,000A Interrupting
When installed according to the
accompanying instructions this unit meets:
- UL 508
- EN 61010
- EN 60204
- EN 954-1 (Class 2)
- Semi S2
- EN 50081-2
- EN 50082-2
Teknic, Inc.
F
e
785
20
20
Remove all screws
from top panel (11 total)
Remove one screw
from front panel
Screw locations on top and front panels of eF-785
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
81
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Summary of Contents for EF-785
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Page 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Page 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Page 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Page 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Page 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Page 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Page 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Page 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...