Paragraph 4 – Setting the Maximum Flow 

Programming Operation 

-

-

-

Pump Functions

Max flow rate

Max flow rate

Max flow rate

P100% 

P100% 

F320s/m 

PROG

-

+

-

+

-

This makes it possible to set the maximum flow offered by 
the pump, and the programmed mode (% or frequency) is 
used as the standard unit of measurement when displaying 

the flow. Changes can be made by pressing the 

 key, 

then using the 

 

 keys to set the new value. Press 

 to confirm and return to the main menu 

 

 
 
Paragraph 5 – Setting the Alarm Relay 

Programming Operation 

-

-

-

-

Pump Functions

Max flow rate

Alarm Relay

P100% 

N.Open

PROG

+

-

 

This is used to set the alarm relay in the absence of an 
alarm situation, if open (default) or closed. 

Changes can be made by pressing the 

 key, then using 

the 

 

 keys to set the new value. Press 

 to 

confirm and return to the main menu 

 

 
 
Paragraph 6 – Flow rate Calibration 

Programming Operation 

-

-

-

-

Pump Calibration

Pump Calibration

Automatic Cal.

Automatic Cal.

Automatic Cal.

Pump Calibration

0,23 cc/stroke

cc/stroke  0,23

Start 100 strok.

Strokes       100

ml             20

Manual

PROG

+

-

+

-

Pump Calibration

Automatic

 

The memorised cc value per strike appears in the main 
menu. It can be calibrated in two different ways: 
MANUAL – manually enter the cc value per strike using the 

 

 keys and confirm by pressing the 

 key 

AUTOMATIC – the pump makes 100 strikes, which are 

started by pressing the 

 key. At the end of this process, 

enter the quantity sucked up by the pump using the 

 

 

keys and confirm by pressing the 

 key. 

The entered figure will be used in flow calculations. 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for TCK

Page 1: ...nction only flow alarm and active memory alarm it deactivates the signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decreas...

Page 2: ...nute of no activity Any data entered in these circumstances will not be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit No Save Save to confirm the selection Pump Funtions Configuration Pump Functions Pump Functions Timer PROG Pump Functions Weekly Timer Manual N Open Paragraph 1 Paragraph 4 Paragraph 5 Paragraph 6 Paragraph...

Page 3: ...nd the flow can only be regulated manually by pressing the keys at the same time in order to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key MAN F F F Lev Stop P100 Operating mode Man Manual Alarms and statuses Lev Level alarm Flw Flow alarms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosa...

Page 4: ...ed by pressing the key in Off mode the relay is not switched off open and in after mode the relay closes when dosage is activated and remains closed once dosage is completed for the time in seconds set using the keys and then confirmed by pressing the key In before mode the relay closes before the dosage activation time for the time in seconds set using the keys and then confirmed by pressing the ...

Page 5: ... the pump doses a quantity that can be programmed in ml It is possible to set a delay time before the dosing Delay and the interval between subsequent dosings Interv as illustrated in the diagram By setting for example an Interval time 0 a system is obtained in which the programmed quantity is dosed after each TRIGGER signal with any delay that has been set It is possible to start the dosing by pr...

Page 6: ...sings Interval as illustrated in the diagram The Delay and Interval times are in dd hh mm days hours minutes The Pause input can be programmed in three different modes 1 FreezeTime when the pause is activated the system cuts out the current time count and restarts it when the pause is deactivated 2 Pause Dosing with the pause activated the system continues to count time the and stops the dosing 3 ...

Page 7: ...ion if open default or closed Changes can be made by pressing the key then using the keys to set the new value Press to confirm and return to the main menu Paragraph 6 Flow rate Calibration Programming Operation Pump Calibration Pump Calibration Automatic Cal Automatic Cal Automatic Cal Pump Calibration 0 23 cc stroke cc stroke 0 23 Start 100 strok Strokes 100 ml 20 Manual PROG Pump Calibration Au...

Page 8: ...ord Password 0000 PROG By entering the password you can enter the programming menu and see all the set values The password will be requested whenever you seek to modify them The flashing line indicates the number than can be modified Use the key to select the number from 1 to 9 and the key to select the number to be modified Confirm by pressing the key By setting 0000 default the password is elimi...

Page 9: ...menu Paragraph 12 Setting the Pause Programming Operation Paus N Aperto PROG Configurazione The pump can be paused by remote input The factory setting is Normally Open Changes can be made by pressing the key then using the keys to set the new value N OPEN or N CLOSED Press to confirm and return to the main menu Display contrast adjustment For adjusting the display contrast keep the key pressed and...

Reviews: