EM00136064                                                                           rev. 2.1 

6

Display during Operation 

Display during Setting (MODE key) 

Timer  

F

F

F

      7,0 ml 

      Stop     P 0%

 

Operating mode 

• 

Timer        

 

 

Alarms and statuses 

• 

Liv = level alarm 

• 

Flow = flow alarm or 
….Release wait 

FLOW  

sensor status 

Programmed value 

• 

Quantity in ml 

Pump status 

• 

Dry = pump starting up 

• 

Stop = pump stop 

• 

Restart = pump restart 

Value of the dosing in 
progress 

• 

Percentage of 
strokes/min 
max 

 

Q.tà         20,0ml 
 20,0ml      P 100% 

Operating mode 

• 

The following are shown in sequence: 
quantity to dose, delay in d.hh.mm. 
and interval in d.hh.mm 

Dosing value 

• 

Programmed 
quantity in m

l

 

Value of the dosing percentage, 
which can be modified by 
pressing the + or – keys 

 

 
Paragraph 3 – Timed Dosage 

(Frequency signal input “TRIGGER” not activated)

 

Programming Operation 

+

-

-

-

-

+

-

+

-

+

-

Tempo

Quantity    100ml

Delay     0.01.50

Interval   0.01.50

PROG

Time

Time      g.hh.mm

Time      g.hh.mm

Configuration

Pum functions

Configuration

Pum functions

-
-

Trigger Mode

Pause Input Mode

Disable

Restart Timer

+

-

-

Pause Input Mode

Restart Timer

-

Pause Input Mode

Freeze Time

Pause Input Mode

Pause Dosing

 

The pump doses a programmed quantity in ml. It is possible to set a 
pump delay time (

Delay

) when the pump is started and an interval 

between two successive dosings (

Interval

), as illustrated in the 

diagram: 
 
 
 
 
 
 
 
 
 
The 

Delay

 and 

Interval

 times are in dd.hh.mm (days, hours, 

minutes) 
 
The 

Pause

 input can be programmed in three different modes: 

1. 

FreezeTime:

 when the pause is activated, the system cuts 

out the current time count and restarts it when the pause is 
deactivated. 

2. 

Pause Dosing:

 with the pause activated, the system 

continues to count time the and stops the dosing. 

3. 

Restart Timer

: when the pause is activated, the system 

stops the dosing and when the pause is deactivated the 
count starts again from the beginning. 

Durante la fase di funzionamento della pompa, è possibile 
modificare la frequenza di dosaggio premendo 

contemporaneamente i tasti 

  

 per aumentare la frequenza 

oppure i tasti 

  

 per diminuirla.

 

 

Display during Operation

 

Display at start-up (MODE key)

 

Timer  

F

F

F

      7.0 ml

Liv    Stop    P 0%

 

Operating mode 

• 

Timer

 

 

• 

Alarms and Level 
statuses = level alarm 

• 

Flow = flow alarm 

FLOW 

sensor 

status 

Programmed value

• 

Quantity in ml 

Pump status 

• 

Dry = pump starting up 

• 

Stop = pump stopping 

• 

Restart = pump restarting 

Value of dosing in 
progress: 

• 

Percentage of 
strokes/min max

 

 

Q.tà         20,0ml   

20,0ml

P 100%

Modalità di funzionamento 

 

Vengono visualizzati in 
sequenza:quantità da 
dosare, ritardo in g.hh.mm e 
intervallo in g.hh.mm 

Valore del dosaggio 

 

Quantità 
programmata in 
ml 

Valore della percentuale di 
dosaggio, modificabile premendo 
sui tasti + o - 

 

 
 

Delay 

Interv.

Quantity 

Summary of Contents for TCK

Page 1: ...nction only flow alarm and active memory alarm it deactivates the signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decreas...

Page 2: ...nute of no activity Any data entered in these circumstances will not be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit No Save Save to confirm the selection Pump Funtions Configuration Pump Functions Pump Functions Timer PROG Pump Functions Weekly Timer Manual N Open Paragraph 1 Paragraph 4 Paragraph 5 Paragraph 6 Paragraph...

Page 3: ...nd the flow can only be regulated manually by pressing the keys at the same time in order to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key MAN F F F Lev Stop P100 Operating mode Man Manual Alarms and statuses Lev Level alarm Flw Flow alarms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosa...

Page 4: ...ed by pressing the key in Off mode the relay is not switched off open and in after mode the relay closes when dosage is activated and remains closed once dosage is completed for the time in seconds set using the keys and then confirmed by pressing the key In before mode the relay closes before the dosage activation time for the time in seconds set using the keys and then confirmed by pressing the ...

Page 5: ... the pump doses a quantity that can be programmed in ml It is possible to set a delay time before the dosing Delay and the interval between subsequent dosings Interv as illustrated in the diagram By setting for example an Interval time 0 a system is obtained in which the programmed quantity is dosed after each TRIGGER signal with any delay that has been set It is possible to start the dosing by pr...

Page 6: ...sings Interval as illustrated in the diagram The Delay and Interval times are in dd hh mm days hours minutes The Pause input can be programmed in three different modes 1 FreezeTime when the pause is activated the system cuts out the current time count and restarts it when the pause is deactivated 2 Pause Dosing with the pause activated the system continues to count time the and stops the dosing 3 ...

Page 7: ...ion if open default or closed Changes can be made by pressing the key then using the keys to set the new value Press to confirm and return to the main menu Paragraph 6 Flow rate Calibration Programming Operation Pump Calibration Pump Calibration Automatic Cal Automatic Cal Automatic Cal Pump Calibration 0 23 cc stroke cc stroke 0 23 Start 100 strok Strokes 100 ml 20 Manual PROG Pump Calibration Au...

Page 8: ...ord Password 0000 PROG By entering the password you can enter the programming menu and see all the set values The password will be requested whenever you seek to modify them The flashing line indicates the number than can be modified Use the key to select the number from 1 to 9 and the key to select the number to be modified Confirm by pressing the key By setting 0000 default the password is elimi...

Page 9: ...menu Paragraph 12 Setting the Pause Programming Operation Paus N Aperto PROG Configurazione The pump can be paused by remote input The factory setting is Normally Open Changes can be made by pressing the key then using the keys to set the new value N OPEN or N CLOSED Press to confirm and return to the main menu Display contrast adjustment For adjusting the display contrast keep the key pressed and...

Reviews: