Paragraph 10 – Level Alarm 

Programming Operation 

-

-

Alarm Level

Alarm Flow

Alarms

Level         Stop

Alarms

Level        Alarm

Stop

Alarm

PROG

-

-

-

ESC

 

This makes it possible to set the pump when the level 
sensor alarm is activated. In other words you can decide 
whether to stop dosage (Stop) or simply activate the alarm 
signal without stopping dosage. 

Changes can be made by pressing the 

 key, then using 

the 

 

 keys to set the alarm type. Confirm by pressing 

the 

 key.  Press 

 to return to the main menu 

Paragraph 11 – Flow Display Unit 

Programming Operation 

-

-

Unit

Unit

Unit

Standard

Standard        <-

L/h

PROG

-

-

+

-

 

measurement on the display. 

Changes can be made by pressing the 

 key, then using 

the 

 

 keys to set the unit of measurement, choosing 

between L/h (litres/hour), Gph (Gallons/hour), ml/m 
(millilitres/minute) or standard (% or frequency, depending 

on settings). Press 

 to confirm and return to the main 

menu 

Paragraph 12 – Setting the Pause 

Programming Operation 

-

-

Paus

N.Aperto

PROG

+

-

Configurazione

+

 

 
The pump can be paused by remote input. 
The factory setting is Normally Open. 

Changes can be made by pressing the 

   key, then 

using the 

 

 keys to set the new value ( N. OPEN or 

N. CLOSED).  
 

Press  

    to confirm and return to the main menu. 

 
Display contrast adjustment.

 

 

For adjusting the display contrast keep the key 

 pressed and within 5 seconds press the keys 

 or 

 to 

increase or decrease the contrast. 

 

Alarms 

Display Cause 

Interruption 

Fixed alarm LED 
Flashing word “Lev” 
I.e.  
 

Man           
Lev           P100%

 

 

 

 

End of level alarm, without 
interrupting pump operation 

Restore the liquid level. 

Fixed alarm LED 
Flashing words “Lev” and “stop” 
I.e.  
 

Man           
Lev   Stop    P100%

 

 

 

 

End of level alarm, with interruption 
to pump operation 

Restore the liquid level. 

Fixed alarm LED 
Flashing word “Flw” 
I.e.  
 

Man    

F

       

Flw           P100%

 

 

 

 

Active flow alarm. The pump has 
not received the programmed 
number of signals from the flow 
sensor. 

Press the 

 key 

 
I.e.  
 

Parameter Error     
PROG to default 

 

 

 

 

Internal CPU communication error. 

Press the 

 key to restore the 

default parameters. 

 

Summary of Contents for TCK

Page 1: ...nction only flow alarm and active memory alarm it deactivates the signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decreas...

Page 2: ...nute of no activity Any data entered in these circumstances will not be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit No Save Save to confirm the selection Pump Funtions Configuration Pump Functions Pump Functions Timer PROG Pump Functions Weekly Timer Manual N Open Paragraph 1 Paragraph 4 Paragraph 5 Paragraph 6 Paragraph...

Page 3: ...nd the flow can only be regulated manually by pressing the keys at the same time in order to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key MAN F F F Lev Stop P100 Operating mode Man Manual Alarms and statuses Lev Level alarm Flw Flow alarms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosa...

Page 4: ...ed by pressing the key in Off mode the relay is not switched off open and in after mode the relay closes when dosage is activated and remains closed once dosage is completed for the time in seconds set using the keys and then confirmed by pressing the key In before mode the relay closes before the dosage activation time for the time in seconds set using the keys and then confirmed by pressing the ...

Page 5: ... the pump doses a quantity that can be programmed in ml It is possible to set a delay time before the dosing Delay and the interval between subsequent dosings Interv as illustrated in the diagram By setting for example an Interval time 0 a system is obtained in which the programmed quantity is dosed after each TRIGGER signal with any delay that has been set It is possible to start the dosing by pr...

Page 6: ...sings Interval as illustrated in the diagram The Delay and Interval times are in dd hh mm days hours minutes The Pause input can be programmed in three different modes 1 FreezeTime when the pause is activated the system cuts out the current time count and restarts it when the pause is deactivated 2 Pause Dosing with the pause activated the system continues to count time the and stops the dosing 3 ...

Page 7: ...ion if open default or closed Changes can be made by pressing the key then using the keys to set the new value Press to confirm and return to the main menu Paragraph 6 Flow rate Calibration Programming Operation Pump Calibration Pump Calibration Automatic Cal Automatic Cal Automatic Cal Pump Calibration 0 23 cc stroke cc stroke 0 23 Start 100 strok Strokes 100 ml 20 Manual PROG Pump Calibration Au...

Page 8: ...ord Password 0000 PROG By entering the password you can enter the programming menu and see all the set values The password will be requested whenever you seek to modify them The flashing line indicates the number than can be modified Use the key to select the number from 1 to 9 and the key to select the number to be modified Confirm by pressing the key By setting 0000 default the password is elimi...

Page 9: ...menu Paragraph 12 Setting the Pause Programming Operation Paus N Aperto PROG Configurazione The pump can be paused by remote input The factory setting is Normally Open Changes can be made by pressing the key then using the keys to set the new value N OPEN or N CLOSED Press to confirm and return to the main menu Display contrast adjustment For adjusting the display contrast keep the key pressed and...

Reviews: