background image

EM00136064                                                                           rev. 2.1 

5

Display during Operation 

Display during Setting (MODE key) 

Weekly  

F

F

F

       Mon 

Lev   Stop    12.01

 

Operating mode 

 

Weekly timer  

Alarms and statuses 

 

Lev = Level alarm 

 

Flw = Flow alarm 

 

Mem = Memory alarm 

FLOW 

sensor 

status 

 

Day of the week 

Displays the quantity during 
dosages 

Pump status 

 

Empty = pump in start 

 

Stop = pump stationary 

 

Paus = pump in pause 

Time 

 

Displays hours 
and minutes

 

P01:START       Mon 
14.40         12.01 

Operating mode 

• 

Displays in sequence: 
programme number, activation 
time, quantity, dosage time, 
relay status. 

• 

Day of the 
week

Time 

• 

Displays hours and minutes 

 

 

 
Paragraph

 

3 – Timed Dosage

 (Frequency signal input “TRIGGER” activated)

 

Programming Operation 

+

-

-
-
-

+

-

+

-

+

-

Time

Quantity    100ml

Delay   0.01.50

interv.    0.01.50

PROG

Time

Time      g.hh.mm

Time       g.hh.mm

Configuration

Pump functions

Configuration

Pump functions

-
-

Trigger Mode

Pause Input Mode

-

Trigger Mode

-

Trigger Mode

Trigger Mode

N. Open

N. Open

N. Closed

Disable

Trigger Mode

 

 
After receipt of the 

TRIGGER

 signal set, the pump doses a quantity 

that can be programmed in ml. It is possible to set a delay time before 
the dosing (

Delay

) and the interval between subsequent dosings 

(

Interv.

) as illustrated in the diagram: 

 
 
 
 
 
 
 
 
 
 
By setting for example an 

Interval.

 time = 0, a system is obtained in 

which the programmed quantity is dosed after each 

TRIGGER

 signal 

(with any delay that has been set): 
 
 
 
 
 
 
 
 
 
It is possible to start the dosing by pressing the + key, which, in 
practice, simulates the 

Trigger

 signal.

 

The 

Trigger

 signal can be set to 

N. Open 

(it is activated when the 

input passes from the open to the closed mode) or to 

N. Closed

 (it is 

activated when the input passes from the closed to the open mode). 
The 

Trigger

 signal is locked during dosing (its receipt is neither stored 

nor managed). 
The 

Pause

  (

Remote input

) input cannot be programmed and its 

activation stops the dosing, while its further deactivation makes the 
system wait again for the 

Trigger

 signal for a new dosing. 

 
The dosage frequency can be modified while the pump is operating, 

by pressing the 

 

 keys at the same time to increase the 

frequency, or the 

 

 keys to decrease it. 

 
 

 
 
 
 
 
 
 
 
 

Delay 

Interv

.

Quantity

Trigger

Delay 

Trigger 

Ritardo 

Release 

Summary of Contents for TCK

Page 1: ...nction only flow alarm and active memory alarm it deactivates the signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decreas...

Page 2: ...nute of no activity Any data entered in these circumstances will not be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit No Save Save to confirm the selection Pump Funtions Configuration Pump Functions Pump Functions Timer PROG Pump Functions Weekly Timer Manual N Open Paragraph 1 Paragraph 4 Paragraph 5 Paragraph 6 Paragraph...

Page 3: ...nd the flow can only be regulated manually by pressing the keys at the same time in order to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key MAN F F F Lev Stop P100 Operating mode Man Manual Alarms and statuses Lev Level alarm Flw Flow alarms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosa...

Page 4: ...ed by pressing the key in Off mode the relay is not switched off open and in after mode the relay closes when dosage is activated and remains closed once dosage is completed for the time in seconds set using the keys and then confirmed by pressing the key In before mode the relay closes before the dosage activation time for the time in seconds set using the keys and then confirmed by pressing the ...

Page 5: ... the pump doses a quantity that can be programmed in ml It is possible to set a delay time before the dosing Delay and the interval between subsequent dosings Interv as illustrated in the diagram By setting for example an Interval time 0 a system is obtained in which the programmed quantity is dosed after each TRIGGER signal with any delay that has been set It is possible to start the dosing by pr...

Page 6: ...sings Interval as illustrated in the diagram The Delay and Interval times are in dd hh mm days hours minutes The Pause input can be programmed in three different modes 1 FreezeTime when the pause is activated the system cuts out the current time count and restarts it when the pause is deactivated 2 Pause Dosing with the pause activated the system continues to count time the and stops the dosing 3 ...

Page 7: ...ion if open default or closed Changes can be made by pressing the key then using the keys to set the new value Press to confirm and return to the main menu Paragraph 6 Flow rate Calibration Programming Operation Pump Calibration Pump Calibration Automatic Cal Automatic Cal Automatic Cal Pump Calibration 0 23 cc stroke cc stroke 0 23 Start 100 strok Strokes 100 ml 20 Manual PROG Pump Calibration Au...

Page 8: ...ord Password 0000 PROG By entering the password you can enter the programming menu and see all the set values The password will be requested whenever you seek to modify them The flashing line indicates the number than can be modified Use the key to select the number from 1 to 9 and the key to select the number to be modified Confirm by pressing the key By setting 0000 default the password is elimi...

Page 9: ...menu Paragraph 12 Setting the Pause Programming Operation Paus N Aperto PROG Configurazione The pump can be paused by remote input The factory setting is Normally Open Changes can be made by pressing the key then using the keys to set the new value N OPEN or N CLOSED Press to confirm and return to the main menu Display contrast adjustment For adjusting the display contrast keep the key pressed and...

Reviews: