Paragraph 7 - Statistics 

Programming Operation 

-

-

-

-

-

-

Statistic

Statistic

Statistic

Statistic Reset

Hours          10

Hours          10

Strokes      1000

NO

PROG

+

-

Statistic

Statistic

Statistic

Q.ty(L)       100

Power         10

Reset

ESC

 

The main menu displays the pump operation times. By 

pressing the 

 key you can access other statistics: 

- Strokes = number of strokes made by the pump 
- Q.ty (L) = quantity dosed by the pump in litres; this figure is 
calculated on the basis of the memorised cc/stroke value 
- Power = number of pump starts 

- Reset = use the 

 

 to reset the counters (YES) or 

otherwise (NO), then confirm by pressing the 

 key. 

 

Pressing the 

 key will take you back to the main menu. 

 
Paragraph 8 – Password 

Programming Operation 

-

-

-

Password

Password

****

0000

PROG

+

-

 

By entering the password, you can enter the programming 
menu and see all the set values. The password will be 
requested whenever you seek to modify them. 
The flashing line indicates the number than can be modified. 

Use the 

 key to select the number (from 1 to 9), and the 

 key to select the number to be modified. Confirm by 

pressing the 

 key. By setting “0000” (default), the 

password is eliminated. 

 

Paragraph 9 – Flow Alarm 

Programming Operation 

-

-

Alarms

Alarms

Alarm Flow

Alarm Flow

Alarm Flow - On

Flow           Off

Flow           Off

Off

On

Signals         6

PROG

+

+

-

-

-

-

-

ESC

 

This makes it possible to activate (deactivate) the flow 
sensor. 

When activated (On), press the 

 key to access the 

request for the number of signals that the pump waits for 
before an alarm is triggered. The number flashes when you 

press the 

 key, and you can then use the 

 

 keys 

to set the value. Confirm by pressing the 

 key. Press 

 to return to the main menu 

 

 
 
 
 
 
 

Summary of Contents for TCK

Page 1: ...nction only flow alarm and active memory alarm it deactivates the signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decreas...

Page 2: ...nute of no activity Any data entered in these circumstances will not be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit No Save Save to confirm the selection Pump Funtions Configuration Pump Functions Pump Functions Timer PROG Pump Functions Weekly Timer Manual N Open Paragraph 1 Paragraph 4 Paragraph 5 Paragraph 6 Paragraph...

Page 3: ...nd the flow can only be regulated manually by pressing the keys at the same time in order to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key MAN F F F Lev Stop P100 Operating mode Man Manual Alarms and statuses Lev Level alarm Flw Flow alarms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosa...

Page 4: ...ed by pressing the key in Off mode the relay is not switched off open and in after mode the relay closes when dosage is activated and remains closed once dosage is completed for the time in seconds set using the keys and then confirmed by pressing the key In before mode the relay closes before the dosage activation time for the time in seconds set using the keys and then confirmed by pressing the ...

Page 5: ... the pump doses a quantity that can be programmed in ml It is possible to set a delay time before the dosing Delay and the interval between subsequent dosings Interv as illustrated in the diagram By setting for example an Interval time 0 a system is obtained in which the programmed quantity is dosed after each TRIGGER signal with any delay that has been set It is possible to start the dosing by pr...

Page 6: ...sings Interval as illustrated in the diagram The Delay and Interval times are in dd hh mm days hours minutes The Pause input can be programmed in three different modes 1 FreezeTime when the pause is activated the system cuts out the current time count and restarts it when the pause is deactivated 2 Pause Dosing with the pause activated the system continues to count time the and stops the dosing 3 ...

Page 7: ...ion if open default or closed Changes can be made by pressing the key then using the keys to set the new value Press to confirm and return to the main menu Paragraph 6 Flow rate Calibration Programming Operation Pump Calibration Pump Calibration Automatic Cal Automatic Cal Automatic Cal Pump Calibration 0 23 cc stroke cc stroke 0 23 Start 100 strok Strokes 100 ml 20 Manual PROG Pump Calibration Au...

Page 8: ...ord Password 0000 PROG By entering the password you can enter the programming menu and see all the set values The password will be requested whenever you seek to modify them The flashing line indicates the number than can be modified Use the key to select the number from 1 to 9 and the key to select the number to be modified Confirm by pressing the key By setting 0000 default the password is elimi...

Page 9: ...menu Paragraph 12 Setting the Pause Programming Operation Paus N Aperto PROG Configurazione The pump can be paused by remote input The factory setting is Normally Open Changes can be made by pressing the key then using the keys to set the new value N OPEN or N CLOSED Press to confirm and return to the main menu Display contrast adjustment For adjusting the display contrast keep the key pressed and...

Reviews: