For hobs CG Lux-60, CG Lux-70, CG Lux-75
and CG Lux-86, which have automatic igni-
tion and a safety feature, the following steps
should be followed:
(See drawing 23)
•
Check that the controls are in the corre c t
position.
•
Open the mains connection gas tap or the
gas bottle cock.
•
Press the burner control.
•
While keeping the burner control pre s s e d ,
turn it as far as it will go until the gas igni-
tes. Keep pressed for 5 to 10 seconds, in
order to permit the safety thermocouple to
be activated.
•
Turn the control to the desired position.
The ignition unit (ceramic and electro d e )
must be carefully cleaned at regular intervals
in order to prevent ignition problems. Also
check that the burner apert u res are not obs-
tructed.
Follow the instructions below in order to ope-
rate a CGC 4G AI AL hob:
(See drawing 24)
•
Check that the control knobs are in the
appropriate position.
•
Open the gas flow key or the gas cylinder
key.
•
P ress the control knob and turn it at the
same time in anti-clockwise direction as far
as it will go to the ignition setting (ignition
illustration). Once gas has been lit, keep
the control knob at this setting for 5 to 10
seconds to let the safety thermocouple act.
•
Set the control knob to the desired posi-
tion.
Burner indicator
Setting indicator
Off setting
Minimum gas setting
Maximum gas setting
On burner setting
For safety reasons we recommend that the
gas supply tap should be turned off when the
cooker is not in use, in accordance with gas
supply company instructions.
If you smell gas, turn off the hob’s gas supply
tap and ventilate the room. The gas installa-
tion and the hob must be checked by a specia-
lized technician.
Warning:
To avoid the risk of burns, keep children away
from the hob during or after its operation.
25
Burner pilot lamp
Control off position
Maximum gas position
Minimum gas position
A
B
D
C
A
B
C
D
A
B
C
D
E
F
A
B
C
D
E
F
Drawing 23